SITRANS P DS III, HART,4-20 MA TRANSMITTER FOR PRESSURE MEASURING CELL FILLING SILICONE OIL, NORMAL CLEuropean Article NumberING SPAN: 0,16 ... 16 BAR G (2.32 ... 232 PSI G), OVERLOAD LIMIT 32 BAR DIAPHRAGM STAINLESS STEEL, MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: MALE THREAD 1/2-14NPT DIE-CAST ALUMINIUM HOUSING STANDARD DESIGN WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND 1/2-14 NPT HOUSING COVER WITH WINDOW

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART,4-20 MA TRANSMITTER FOR PRESSURE MEASURING CELL FILLING SILICONE OIL, NORMAL CLEuropean Article NumberING SPAN: 4,0 ... 400 BAR G (58.0 ... 5802 PSI G), OVERLOAD LIMIT 600 BAR DIAPHRAGM STAINLESS STEEL, MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: CONNECTION SHANK G1/2 B TO EN 837-1 DIE-CAST ALUMINIUM HOUSING INTERNATIONAL DESIGN ENGLISH INSCRIPTION AND DOCUMENTATION AS CD WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X 1.5 WITHOUT VISIBLE DIGITAL INDICATOR (DIGITAL DISPLAY HIDDEN, SETTING: MA)

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III PROFIBUS PA, TRANSMITTER FOR PRESSURE MEASURING CELL FILLING SILICONE OIL, NORMAL CLEuropean Article NumberING NOMINAL MEASURING RANGE 1 BAR G (14.5 PSI G), OVERLOAD LIMIT 6 BAR DIAPHRAGM STAINLESS STEEL, MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: MALE THREAD 1/2-14NPT DIE-CAST ALUMINIUM HOUSING INTERNATIONAL VERSION ENGLISH INSCRIPTION AND DOCUMENTATION ON CD WITHOUT EXPLOSION PROTECTION ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND 1/2-14 NPT WITHOUT VISIBLE DIGITAL INDICATOR (DIGITAL DISPLAY HIDDEN, SETTING: MA)

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III / P410, PROFIBUS PA, transmitter

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 160 (MWP 2320 PSI): 2,5 TO 250 MBAR (1.004 TO 100.4 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: M10 DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL STANDARD DESIGN . WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X1.5 WITHOUT VISIBLE DIGITAL INDICATOR (DIGITAL DISPLAY HIDDEN, SETTING: MA)

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 160 (MWP 2320 PSI): 2,5 TO 250 MBAR (1.004 TO 100.4 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: M10 DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL INTERNATIONAL DESIGN ENGLISH INSCRIPTION DOCUMENTATION AS CD WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X1.5 WITHOUT VISIBLE DIGITAL INDICATOR (DIGITAL DISPLAY HIDDEN, SETTING: MA)

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 160 (MWP 2320 PSI): 2,5 TO 250 MBAR (1.004 TO 100.4 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: 7/16-20 UNF DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL STANDARD DESIGN . WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND 1/2-14 NPT HOUSING COVER WITH WINDOW

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 160 (MWP 2320 PSI): 2,5 TO 250 MBAR (1.004 TO 100.4 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: 7/16-20 UNF DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL INTERNATIONAL DESIGN ENGLISH INSCRIPTION DOCUMENTATION AS CD WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X1.5 HOUSING COVER WITH WINDOW

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 160 (MWP 2320 PSI): 6 TO 600 MBAR (2.409 TO 240.9 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: M10 DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL STANDARD DESIGN . WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND 1/2-14 NPT WITHOUT VISIBLE DIGITAL INDICATOR (DIGITAL DISPLAY HIDDEN, SETTING: MA)

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 160 (MWP 2320 PSI): 6 TO 600 MBAR (2.409 TO 240.9 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: 7/16-20 UNF DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL STANDARD DESIGN . WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND 1/2-14 NPT HOUSING COVER WITH WINDOW

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 160 (MWP 2320 PSI): 16 TO 1600 MBAR (6.424 TO 642.4 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: 7/16-20 UNF DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL STANDARD DESIGN . WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND 1/2-14 NPT HOUSING COVER WITH WINDOW

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 160 (MWP 2320 PSI): 16 TO 1600 MBAR (6.424 TO 642.4 INH2O), MAX. STATIC PRESSURE 160 BAR DESIGN FOR REMOTE SEALS. NOTE: PLEASE ADD THE DELIVERY TIME OF THE REMOTE SEAL! PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: 7/16-20 UNF DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL STANDARD DESIGN . WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X1.5 HOUSING COVER WITH WINDOW

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 160 (MWP 2320 PSI): 50 TO 5000 MBAR (20.08 TO 2008 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: M10 DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL INTERNATIONAL DESIGN ENGLISH INSCRIPTION DOCUMENTATION AS CD WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X1.5 HOUSING COVER WITH WINDOW
DIAPHRAGM SEAL DIRECTLY MOUNTED TYPE 7MF4912, . PRESSURE EQUIPMENT DIRECTIVE F GAS 1/LIQUIDS 1 ART. 3.3 SEP DIRECTLY MOUNTED ON SITRANS P TRANSMITTER FOR LEVEL, DS SERIES, PROCESS CONNECTION ACC. EN 1092-1 / ASME B16.5 NOM. DIAMETER, NOM. PRESSURE: DN 80, PN 40 WETTED PARTS: STAINLESS STEEL, WITHOUT FOIL, EXTENSION 0 MM TRANSMISSION FLUID: SILICON OIL M5
DIAPHRAGM SEAL DIRECTLY MOUNTED TYPE 7MF4912, . PRESSURE EQUIPMENT DIRECTIVE F GAS 1/LIQUIDS 1 ART. 3.3 SEP DIRECTLY MOUNTED ON SITRANS P TRANSMITTER FOR LEVEL, DS SERIES, PROCESS CONNECTION ACC. EN 1092-1 / ASME B16.5 NOM. DIAMETER, NOM. PRESSURE: 3 INCH, CLASS 150 WETTED PARTS: STAINLESS STEEL, WITHOUT FOIL, EXTENSION 0 MM TRANSMISSION FLUID: SILICON OIL M5
COVER (DIE-CAST ALUMINIUM) WITH WINDOW INCL.O-RING FOR SERIES SITRANS P DSIII, DSIII PA AND DSIII FF

HART-MODEM WITH USB- INTERFACE

SITRANS P TRANSMITTER COMPACT FOR PRESSURE AND ABSOLUT PRESSURE FOR FOOD, PHARMACEU- TICALS AND BIOTECHNOLOGY, WITH DIAPHRAGM FLUSH AT FRONT. 2-WIRE SYSTEM, PROCESS TEMPERA- TURE UP TO 140 DEG. CEL., ACCURACY 0.2 % OF F.S.V. OUTPUT SIGNAL: 4...20 MA, PROCESS CONNECTION: QUICK-RELEASE CONNECTION: CLAMP CONNECTION ACCORDING ISO 2852: 1 INCH FILLING LIQUID: LIQUID FDA APPROVED OUTPUT SIGNAL : 4-20 MA HOUSING(STAINLESS STEEL1.4404)/ ELECTRICAL CONNECTION: FIELD HOUSING STAINLESS STEEL WITH CABLE GLAND, IP67 MEASURING RANGE: 0...1 BAR OVERLOAD PRESSURE: 10 BAR WITHOUT EXPLOSION PROTECTION
SITRANS P TRANSMITTER COMPACT FOR PRESSURE AND ABSOLUT PRESSURE FOR FOOD, PHARMACEU- TICALS AND BIOTECHNOLOGY, WITH DIAPHRAGM FLUSH AT FRONT. 2-WIRE SYSTEM, PROCESS TEMPERA- TURE UP TO 140 DEG. CEL., ACCURACY 0.2 % OF F.S.V. OUTPUT SIGNAL: 4...20 MA, PROCESS CONNECTION: QUICK-RELEASE CONNECTION: SMS-NORM WITH SCREW NECKS: 1 INCH FILLING LIQUID: LIQUID FDA APPROVED OUTPUT SIGNAL : 4-20 MA HOUSING(STAINLESS STEEL1.4404)/ ELECTRICAL CONNECTION: HOUSING WITH ANGELD PLUG ACCORDING DIN 43650, IP65 MEASURING RANGE: 0...1 BAR OVERLOAD PRESSURE: 10 BAR WITHOUT EXPLOSION PROTECTION

DOUBLE SHUT-OFF COCK DN 5 MAT. NO. 1.4404, MAX. OPERATING PRESSURE 420 BAR PRESSURE EQUIPMENT DIREKTIVE F. GAS 1/LIQUIDS 1 ART. 3.3 SEP

DOUBLE SHUT-OFF COCK DN 5 (SLEEVE - JOURNAL), MAT. NO. 1.4404, MAX. OPERATING PRESSURE 420 BAR PRESSURE EQUIPMENT DIREKTIVE F. GAS 1/LIQUIDS 1 ART. 3.3 SEP
DOUBLE SHUT-OFF COCK DN 5 (JOURNAL - JOURNAL), MAT. NO. 1.4404, MAX. OPERATING PRESSURE 420 BAR PRESSURE EQUIPMENT DIREKTIVE F. GAS 1/LIQUIDS 1 ART. 3.3 SEP
DOUBLE SHUT-OFF COCK DN 5 (SLEEVE - SLEEVE), MAT.NO. 1.4404, MAX. OPERATING PRESSURE 420 BAR PRESSURE EQUIPMENT DIREKTIVE FOR GAS 1/LIQUIDS 1 ART. 3.3 SEP
DOUBLE SHUT-OFF COCK DN 5 (COLLAR - SLEEVE), MAT. NO. 1.4404, MAX. OPERATING PRESSURE 420 BAR PRESSURE EQUIPMENT DIREKTIVE FOR GAS 1/LIQUIDS 1 ART. 3.3 SEP
DOUBLE SHUT-OFF VALVE DESIGN B, DIN 16272, WITH TEST AND CONNECTION COLLARS, MAX. OPERATING PRESSURE 400 BAR MAT. NO. 1.4571 PRESSURE EQUIPMENT DIREKTIVE F. GAS 1/LIQUIDS 1 ART. 3.3 SEP
DOUBLE SHUT-OFF VALVE DESIGN B, DIN 16272, WITH TEST COLLAR, PIPE UNION, MAT. NO. 1.4571, MAX. OPERATING PRESSURE 400 BAR PRESSURE EQUIPMENT DIREKTIVE F. GAS 1/LIQUIDS 1 ART. 3.3 SEP
3-SPINDLE VALVE MANIFOLD DN 5 FOR DIREKT FLANGING TO TRANSMITTERS, MAX. OPERATING PRESSURE 420 BAR PROCESS CONNECTION 1/2",-14 NPT- F. CONNECTION AT TRANSMITTER ACC. EN 61518 FORM B WITHOUT CERTIFICATE

Siemens 7MH5113-4LD00 rated load 3,5T, C3, 6 M cable length, 4 conductors,  protection class IP68

MOTION FAILURE ALARM MFA 4P: HIGHLY SENSITIVE SINGLE SET POINT MOTION SENSOR ALARM UNIT USED WITH MSP AND XPP PROBES ENCLOSURE: NEMA 4X, POLYCARBONATE ENCLOSURE INPUT VOLTAGE: 100/115/200/230 VAC, 50/60 HZ, SWITCH SELECTABLE. SPEED DETECTION VERSION: STANDARD, UNDERSPEED (U/S) OR OVERSPEED (O/S), SWITCH SELECTABLE APPROVALS: CE, CSA US/C, FM
REMOTE MOUNTED AMPLIFIER(RMA): REMOTE MOUNTED AMPLIFIER FOR MILLTRONICS MSP-1, MSP-3 AND MSP-9 MOTION SENSING PROBES . ENCLOSURE: ALUMINIUM ENCLOSURE, 1/2", NPT ENTRY