Baumer Absolute encoders

Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.100 mA (5 VDC, w/o load)
50 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Operating temperature-20...+85 °C
InputsSSI clock
Zero setting input
Voltage supply10...30 VDC
Consumption typ.50 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Interface12 parallel outputs
Operating temperature-20...+85 °C
Voltage supply10...30 VDC
Consumption typ.100 mA (24 VDC, w/o load)
Sensing methodMagnetic
Operating temperature-20...+85 °C
Voltage supply5 VDC ±10 %
Consumption typ.100 mA (5 VDC, w/o load)
Sensing methodMagnetic
Interface9 parallel outputs
Operating temperature-20...+85 °C
Voltage supply10...30 VDC
Consumption typ.50 mA (24 VDC, w/o load)
Sensing methodMagnetic
Interface12 parallel outputs
Operating temperature-20...+85 °C
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.100 mA (5 VDC, w/o load)
50 mA (24 VDC, w/o load)
Sensing methodMagnetic
Operating temperature-20...+85 °C
InputsSSI clock
Zero setting input
Voltage supply10...30 VDC
Consumption typ.100 mA (24 VDC, w/o load)
Initializing time typ.500 ms after power on
Operating temperature-20...+65 °C
Voltage supply10...30 VDC
Consumption w/o load≤200 mA (24 VDC)
Initializing time≤250 ms after power on
Operating temperature-40...+85 °C (see general informations)
Voltage supply10...30 VDC
Consumption typ.50 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Interface12 parallel outputs
Operating temperature-20...+85 °C
Voltage supply10...30 VDC
Consumption w/o load≤200 mA (24 VDC)
Initializing time≤250 ms after power on
Operating temperature-40...+85 °C (see general informations)
Voltage supply10...30 VDC
Consumption typ.50 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Interface12 parallel outputs
Operating temperature-20...+85 °C
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption w/o load≤150 mA (5 VDC)
≤60 mA (24 VDC)
Initializing time typ.170 ms after power on
Operating temperature-40...+85 °C (see general informations)
InputsSSI clock: Linereceiver RS422
Zero setting input

Voltage supply: 10...30 VDC

  • Absolute encoder multiturn
  • Optical sensing method
  • Max. resolution: singleturn 18В bit, multiturn 16 bit
  • Blind hollow shaft
  • LED status display
  • EtherCAT
  • Maximum resistant against magnetic fields
  • Absolute encoder multiturn
  • Optical sensing method
  • Max. resolution: singleturn 18В bit, multiturn 16 bit
  • Blind hollow shaft
  • LED status display
  • EtherNet/IP
  • Maximum resistant against magnetic fields
  • Button for Preset/Reset
  • Rotary coding switch for IP address
  • Absolute encoder multiturn
  • Optical sensing method
  • Max. resolution: singleturn 18В bit, multiturn 16 bit
  • Blind hollow shaft
  • LED status display
  • PROFINET IO
  • Maximum resistant against magnetic fields
  • Absolute encoder multiturn
  • Optical sensing method
  • Max. resolution: singleturn 18В bit, multiturn 16 bit
  • Clamping flange
  • LED status display
  • PROFINET IO
  • Maximum resistant against magnetic fields
  • Absolute encoder multiturn
  • Optical sensing method
  • Max. resolution: singleturn 18В bit, multiturn 16 bit
  • Synchro flange
  • LED status display
  • PROFINET IO
  • Maximum resistant against magnetic fields
  • Absolute encoder multiturn
  • Optical sensing method
  • Max. resolution: singleturn 18В bit, multiturn 16 bit
  • Through hollow shaft
  • LED status display
  • EtherCAT
  • Maximum resistant against magnetic fields
  • Absolute encoder multiturn
  • Optical sensing method
  • Max. resolution: singleturn 18В bit, multiturn 16 bit
  • Through hollow shaft
  • LED status display
  • EtherNet/IP
  • Maximum resistant against magnetic fields
  • Button for Preset/Reset
  • Rotary coding switch for IP address
  • Absolute encoder multiturn
  • Optical sensing method
  • Max. resolution: singleturn 18В bit, multiturn 16 bit
  • Through hollow shaft
  • LED status display
  • PROFINET IO
  • Maximum resistant against magnetic fields
  • Encoder singleturn / Analog
  • Contactless measuring method
  • Robust magnetic sensing
  • Simple mouting, long service life
  • Designed for harsh environmental conditions
  • Operating temperature -40...+85 В°C
  • Resolution: 12 bit
  • Redundant version available
  • Protection IP 65 or IP 67
  • Encoder singleturn / CANopenВ®
  • Contactless measuring method
  • Robust magnetic sensing
  • Simple mouting, long service life
  • Designed for harsh environmental conditions
  • Operating temperature -40...+85 В°C
  • Resolution 14 bit
  • Redundant version available
  • Protection IP 65 or IP 67
  • Encoder single- or multiturn / CANopenВ®
  • Precise magnetic sensing
  • Angular accuracy up to В±0.15В°
  • High protection up to IP 67
  • High resistance to shock and vibrations
  • Electronic gear function
  • Radial or axial plug and cable connection
  • Encoder single- or multiturn / SSI
  • Precise magnetic sensing
  • Angular accuracy up to В±0.15В°
  • Resolution max. 32 bit (14 bit ST, 18 bit MT)
  • High resistance to shock and vibrations
  • High protection up to IP 67
  • Radial or axial plug and cable connection
  • Encoder single- or multiturn / SSI
  • Precise magnetic sensing
  • Angular accuracy up to В±0.15В°
  • Resolution max. 32 bit (14 bit ST, 18 bit MT)
  • High resistance to shock and vibrations
  • High protection up to IP 67
  • Radial or axial plug and cable connection
  • Encoder single- or multiturn / CANopenВ®
  • Precise magnetic sensing
  • Angular accuracy up to В±0.15В°
  • Additional incremental signals
  • High protection up to IP 67
  • High resistance to shock and vibrations
  • Electronic gear function
  • Encoder single- or multiturn / SSI
  • Precise magnetic sensing
  • Angular accuracy up to В±0.15В°
  • Resolution max. 32 bit (14 bit ST, 18 bit MT)
  • Additional incremental signals
  • Clock frequency up to 2 MHz
  • High resistance to shock and vibrations
  • High protection up to IP 67
  • Encoder kit single- or multiturn / CANopenВ®
  • Precise magnetic sensing
  • Angular accuracy up to В±0.15В°
  • Additional incremental signals
  • High protection up to IP 67
  • High resistance to shock and vibrations
  • Electronic gear function
  • Encoder kit single- or multiturn / SSI
  • Precise magnetic sensing
  • Angular accuracy up to В±0.15В°
  • Resolution max. 32 bit (14 bit ST, 18 bit MT)
  • Additional incremental signals
  • Clock frequency up to 2 MHz
  • High protection up to IP 67
  • High resistance to shock and vibrations