IFM Electronic AC570A
AS-Interface systems and sensors
AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via AS-i, 5/3-way slide valve free from overlapping, closed, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection
Item Number:
AC570A
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Voltage range: | 20...30 DC V |
Outputs: | |
Shortcode: | AirBox 5/3 closed 4DI II 3D |
Operating pressure range: | 3...8 [bar] |
Operating voltage: | 26.5...31.6 V DC |
Protection: | IP 50 |
Operation: | LED green |
Ambient temperature: | -10...50 °C |
Total current consumption from AS-i: | < 280 mA |
Pneumatic system: | 1 x 5/3-way slide valve (free from overlapping), middle position blocked |
Error: | LED Red |
Electrical design: | 4 inputs / 2 outputs, AirBox supply via AS-i |
SKU | HDT0NCZ9J0ZJED |
Output function: | common exhaust with tube connection |
Sensor supply: | AS-i |
Housing materials: | PA, POM, Piercing contacts: CuSn6 surface nickel and tin-plated |
Function display: | LED yellow |
Product Name: | AC570A |
Circuit: | DC PNP |
People also buy
Comments
No comments yet