Pepperl+Fuchs NCB2-V3-N0-Y244943
Inductive sensor

Pepperl+Fuchs NCB2-V3-N0-Y244943
  • 2 mm flush
  • Usable up to SIL 2 acc. to IEC 61508
Item Number: NCB2-V3-N0-Y244943
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments
Appropriate typeNCB2-V3-N0...
Core cross-section0.14 mm2
ATEX marking II 1G Ex ia IIC T6…T1 Ga
The Ex-related marking can also be printed on the enclosed label.
Effective internal inductancemax. 100 µH
Assured operating distance0 ... 1.62 mm
Appropriate typeNCB2-V3-N0...
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
Hysteresistyp. 3 %
Switching functionNormally closed (NC)
ATEX marking II 1G Ex ia IIC T6…T1 Ga
The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012
Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions
Effective internal capacitancemax. 100 nF
Output type2-wire
Effective internal inductancemax. 100 µH
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1.
Switching frequency0 ... 2000 Hz
Nominal voltage8.2 V (Ri approx. 1 kΩ)
ATEX marking II 1D Ex ia IIIC T135В°C Da
The Ex-related marking can also be printed on the enclosed label.
Effective internal capacitancemax. 100 nF
Installationflush
Ambient temperature-25 ... 100 В°C (-13 ... 212 В°F)
CE marking[*PD-Z02585A*]
Diagnostic Coverage (DC)0 %
CSA approvalcCSAus Listed, General Purpose
MTTFd2180 a
Mission Time (TM)20 a
CE marking[*PD-Z02585A*]
Reduction factor rCu 0.2
Reduction factor rAl 0.3
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012
Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
Use in the hazardous areasee instruction manuals
Housing materialPBT
Effective internal inductancemax. 100 µH
Rated operating distance2 mm
Output typeNAMUR
Sensing facePBT
Connection typecable PVC , 130 mm
Insulated wire end ferrule with 8 mm pin length
Effective internal capacitancemax. 100 nF
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012
Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
Degree of protectionIP67
CE marking[*PD-Z02585A*]
Switching state indicatorLED, yellow
Reduction factor r304 0.7
Appropriate typeNCB2-V3-N0...

Comments