Pepperl+Fuchs NJ15-M1K-N-Y127931
Inductive sensor
- Comfort series
- 15 mm non-flush
- Overview
- Comments
Appropriate type | NJ15-M1K-N... |
Reduction factor rCu | 0.4 |
Switching frequency | 0 ... 100 Hz |
Switching state indicator | LED, yellow |
MTTFd | 2424 a |
Housing material | PBT |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
CE marking | [*PD-Z02585A*] |
Diagnostic Coverage (DC) | 0 % |
CE marking | [*PD-Z02585A*] |
Rated operating distance | 15 mm |
Ambient temperature | -25 ... 100 В°C (-13 ... 212 В°F) |
Mission Time (TM) | 20 a |
Sensing face | PBT |
Effective internal capacitance | max. 130 nF ; a cable length of 10 m is considered. |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
Connection type | screw terminals |
CSA approval | cCSAus Listed, General Purpose |
Output type | 2-wire |
Nominal voltage | 8.2 V (Ri approx. 1 kΩ) |
Assured operating distance | 0 ... 12.15 mm |
Core cross-section | up to 2.5 mm2 |
Output type | NAMUR |
Use in the hazardous area | see instruction manuals |
Degree of protection | IP67 |
ATEX marking | II 2G Ex ia IIC T6…T1 Gb The Ex-related marking can also be printed on the enclosed label. |
Reduction factor r304 | 0.8 |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. |
Appropriate type | NJ15-M1K-N... |
Effective internal inductance | max. 80 µH A cable length of 10 m is considered. |
Installation | non-flush |
Reduction factor rAl | 0.45 |
UL approval | cULus Listed, General Purpose |
Actual operating distance | 13.5 ... 16.5 mm typ. |
Effective internal inductance | max. 80 µH ; a cable length of 10 m is considered. |
Effective internal capacitance | max. 130 µF A cable length of 10 m is considered. |
ATEX marking | II 1D Ex ia IIIC T135В°C Da The Ex-related marking can also be printed on the enclosed label. |
Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % |
Switching function | Normally closed (NC) |
People also buy
Comments
No comments yet