Pepperl+Fuchs NJ6-22-N-15M
Inductive sensor

Pepperl+Fuchs NJ6-22-N-15M
  • Comfort series
  • 6 mm flush
  • Usable up to SIL 2 acc. to IEC 61508
Item Number: NJ6-22-N-15M
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments
Switching functionNormally closed (NC)
ATEX marking II 2G Ex ia IIC T6…T1 Gb
The Ex-related marking can also be printed on the enclosed label.
CSA approvalcCSAus Listed, General Purpose
Reduction factor rAl 0.4
ATEX marking II 3G Ex ic IIC T6…T1 Gc
The Ex-related marking can also be printed on the enclosed label.
Hysteresis1 ... 7 typ. 4 %
Housing materialPBT
Appropriate typeNJ 6-22-N...
Output typeNAMUR
Diagnostic Coverage (DC)0 %
UL approvalcULus Listed, General Purpose
Effective internal inductancemax. 100 µH ; A cable length of 10 m is considered.
Effective internal capacitancemax. 130 nF ; a cable length of 10 m is considered.
CE marking[*PD-Z02586A*]
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012
Ignition protection category ""ic""
Use is restricted to the following stated conditions
CE marking[*PD-Z02585A*]
CE marking[*PD-Z02585A*]
Assured operating distance0 ... 4.86 mm
ATEX marking II 1D Ex ia IIIC T135В°C Da
The Ex-related marking can also be printed on the enclosed label.
Reduction factor r304 0.85
Core cross-section0.75 mm2
Effective internal capacitancemax. 130 µF
A cable length of 10 m is considered.
Degree of protectionIP68
CCC approvalCCC approval / marking not required for products rated ≤36 V
Effective internal inductancemax. 100 µH ; a cable length of 10 m is considered.
Appropriate typeNJ 6-22-N...
MTTFd4566 a
Switching frequency0 ... 2000 Hz
Effective internal capacitancemax. 130 nF ; a cable length of 10 m is considered.
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012
Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
Ambient temperature-25 ... 100 В°C (-13 ... 212 В°F)
Sensing facePBT
Reduction factor rCu 0.3
CertificatePF 13 CERT 2895 X
Effective internal inductancemax. 100 µH
A cable length of 10 m is considered.
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate.
Nominal voltage8 V
Rated operating distance6 mm
Installationflush
Output type2-wire
Use in the hazardous areasee instruction manuals
Connection typecable PVC , 2 m
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012
Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
Mission Time (TM)20 a