CE marking | [*PD-Z02585A*] |
CE marking | [*PD-Z02585A*] |
Appropriate type | SJ5-K... |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
ATEX marking | II 1G Ex ia IIC T6…T1 Ga The Ex-related marking can also be printed on the enclosed label. |
Output type | NAMUR |
Switching function | Normally closed (NC) |
Connection type | cable PVC , 6 m |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
Highest permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. |
Nominal voltage | 8.2 V (Ri approx. 1 kΩ) |
UL approval | cULus Listed, General Purpose |
Depth of immersion (lateral) | 8 ... 10 typ. 9 mm |
Switching frequency | 0 ... 2000 Hz |
Effective internal capacitance | max. 50 nF ; a cable length of 10 m is considered. |
Slot width | 5 mm |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
Appropriate type | SJ5-K... |
Effective internal inductance | max. 550 µH ; a cable length of 10 m is considered. |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. |
MTTFd | 4560 a |
CSA approval | cCSAus Listed, General Purpose |
Effective internal capacitance | max. 50 nF ; a cable length of 10 m is considered. |
Output type | 2-wire |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient temperature | -25 ... 100 В°C (-13 ... 212 В°F) |
Diagnostic Coverage (DC) | 0 % |
Use in the hazardous area | see instruction manuals |
ATEX marking | II 1D Ex ia IIIC T135В°C Da The Ex-related marking can also be printed on the enclosed label. |
Effective internal inductance | max. 550 µH ; a cable length of 10 m is considered. |
Appropriate type | SJ5-K... |
Mission Time (TM) | 20 a |
CE marking | [*PD-Z02585A*] |
Effective internal capacitance | max. 50 nF ; a cable length of 10 m is considered. |
ATEX marking | II 1G Ex ia IIC T6…T1 Ga The Ex-related marking can also be printed on the enclosed label. |
Housing material | PBT |
Effective internal inductance | max. 550 µH ; a cable length of 10 m is considered. |
Degree of protection | IP67 |
Core cross-section | 0.75 mm2 |