Schneider Electric ATS48C32Q
Soft starter for asynchronous motor

Schneider Electric ATS48C32Q
Product destinationAsynchronous motors
Product specific applicationPumping and ventilation machine
Severe and standard applications
Component nameATS48
Power supply voltage230...415 V (- 15...10 %)
Motor power kW250 kW at 400 V (connection to the motor delta terminals) for standard applications
220 kW at 400 V (connection to the motor delta terminals) for severe applications
160 kW at 400 V (connection in the motor supply line) for standard applications
160 kW at 230 V (connection to the motor delta terminals) for standard applications
132 kW at 400 V (connection in the motor supply line) for severe applications
132 kW at 230 V (connection to the motor delta terminals) for severe applications
90 kW at 230 V (connection in the motor supply line) for standard applications
75 kW at 230 V (connection in the motor supply line) for severe applications
Item Number: ATS48C32Q
5693.25
-
+
Total price: 5693.25
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Product destinationAsynchronous motors
Product specific applicationPumping and ventilation machine
Severe and standard applications
Component nameATS48
Power supply voltage230...415 V (- 15...10 %)
Motor power kW250 kW at 400 V (connection to the motor delta terminals) for standard applications
220 kW at 400 V (connection to the motor delta terminals) for severe applications
160 kW at 400 V (connection in the motor supply line) for standard applications
160 kW at 230 V (connection to the motor delta terminals) for standard applications
132 kW at 400 V (connection in the motor supply line) for severe applications
132 kW at 230 V (connection to the motor delta terminals) for severe applications
90 kW at 230 V (connection in the motor supply line) for standard applications
75 kW at 230 V (connection in the motor supply line) for severe applications
Power dissipation in W902 W for standard applications
695 W for severe applications
Utilisation categoryAC-53A
Type of startStart with torque control (current limited to 5 In)
Icl nominal current554 A (connection to the motor delta terminals)for standard applications
433 A (connection to the motor delta terminals)for severe applications
320 A (connection in the motor supply line)for standard applications
250 A (connection in the motor supply line)for severe applications
IP degree of protectionIP00
Assembly styleWith heat sink
Function availableExternal bypass (optional)
Power supply voltage limits195...456 V
Device Full NameSchneider Electric ATS48C32Q

Comments

No comments yet

Write a comment