  • High-resolution, 30-bit absolute encoder (18 bit singleturn and 12 bit multiturn)
  • Device Level Ring (DLR functionality)
  • Extensive diagnostics: Min/max values for temperature, position, speed. Operating hours counter, display of flags, alarms and warnings using e.g. a fault header (32 bit)
Item Number: AFM60A-S4IB000S02
925.10
-
+
Total price: 925.10
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Sick AFM60A-S4IB000S02 is outdated.

Specification:

Part Number1064852
Flange material:Aluminum
Mechanical interface:Solid shaft with flat, Face mount flange
Repeat accuracy:0.002 °
Storage temperature range:-40 °C ... 100 °C, without package
Operating voltage range:10 V DC ... 30 V DC
Resistance to vibration:30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
Mass:0.2 kg
Shaft diameter:10 mm
Bearing lifetime:3.0 x 10^9 revolutions
Permissible relative humidity:90 % (condensation of the optical scanning not permitted)
Start up torque:0.5 Ncm (20 °C)
Housing material:Aluminum
Maximum operating speed:9,000 /min
Electrical interface:3 x connector M12, 4-pin, axial
Shaft material:Stainless steel
DLR (Device Level Ring):1
Data transmission rate (baud rate):10 Mbit/s / 100 Mbit/s
Resolution:18 bit x 12 bit
Resolution power:262,144 x 4,096
Operating torque:0.3 Ncm (20 °C)
Permissible Load capacity of shaft:40 N (axial), 80 N (radial)
Resistance to shocks:100 g (according to EN 60068-2-27)
Endless operating functionality:1
EMC:(according to EN 61000-6-2 and EN 61000-6-3)
Max. angular acceleration:500,000 rad/s?
Enclosure rating:IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side
Initialization time:Ca. 12 s
Max. number of steps per revolution:262,144
Power consumption max.:3 W
Working temperature range:-30 °C ... 85 °C
Error limits:± 0.03 °
Encoder profile:0 x 22
Bus interface:EtherNet/IP IEC 61784-1
Moment of inertia of the rotor:6.2 gcm?
Measuring step deviation:± 0.002 °
RPI (requested packet interval):5 ms ... 750 ms
MTTFd: mean time to dangerous failure:80 a (EN ISO 13849-1)
Max. number of revolutions:4,096