+421 552 601 099
+1 888 384-58-19

AFM60A-TGPM262144
Absolute encoders

General specification:

Specification:

Part NumberAFM60A-TGPM262144
Clock frequency:2 MHz
Storage temperature range:-40 °C ... 100 °C, without package
Error limits:± 0.03 °
Code type:Gray
Resolution:18 bit x 12 bit
Initialization time:50 ms
CW/CCW (counting sequence when turning):L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V)
Bearing lifetime:3.0 x 10^9 revolutions
Permissible relative humidity:90 % (condensation of the optical scanning not permitted)
Power consumption:0.5 W (without load)
Permissible movement radial static/dynamic:± 0.3 mm, ± 0.05 mm
Start up torque:0.8 Ncm (20 °C)
Interface signals:Clock +, Clock -, Data +, Data-
Max. number of revolutions:4,096
Code sequence:CW/CCW, parameter adjustable
Measuring step:0.014 ° 360 ° / number of steps
Permissible movement axial static/dynamic:± 0.5 mm, ± 0.01 mm
Type of mounting shaft:Through hollow shaft
Max. angular acceleration:500,000 rad/s²
MTTFd: mean time to dangerous failure:250 a (EN ISO 13849-1)
Moment of inertia of the rotor:40 gcm²
Resistance to vibration:20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
Operating voltage range:4.5 V DC ... 32 V DC
Electrical interface:SSI/Gray, programmable
Working temperature range:-30 °C ... 100 °C
SET (electronic adjustment):H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V)
Mechanical interface:Through hollow shaft
Resistance to shocks:60 g, 6 ms (according to EN 60068-2-27)
EMC:(according to EN 61000-6-2 and EN 61000-6-3)
Resolution power:262,144 x 4,096
Maximum operating speed:9,000 /min
Max. number of steps per revolution:262,144
Repeat accuracy:0.002 °
Operating torque:0.6 Ncm (20 °C)
Measuring step deviation:± 0.002 °
Shaft diameter:14 mm
Connection type:Cable, 8-wire, universal, 5 m
Enclosure rating:IP 65 (according to IEC 60529), housing side, IP 65 (according to IEC 60529), shaft side
Reverse polarity protection:1