Sick ATM90-PXF11X13
ATM90 Absolute encoder

Sick ATM90-PXF11X13
  • Extremely rugged, tried-and-tested absolute multiturn encoder with a resolution of up to 26 bits
  • Mechanical interface: through hollow shaft with shallow installation depth
  • Zero-set and preset functions via hardware or software
Item Number: ATM90-PXF11X13
1575.20
-
+
Total price: 1575.20
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1032898
Moment of inertia of the rotor:153 gcm²
Operating torque:0.4 Ncm
Bus interface:RS-485
Enclosure rating:IP 65 (according to IEC 60529), with shaft seal
Measuring step:0.043 °
Bearing lifetime:3.6 x 10^9 revolutions
Resistance to vibration:20 g, 10 Hz ... 2,000 Hz
Mass:0.6 kg
Error limits:± 0.25 °
Max. angular acceleration:600,000 rad/s²
Max. number of steps per revolution:2,048
Mechanical interface:Through hollow shaft
Flange material:Aluminum
Repeat accuracy:0.1 °
Bus:PROFIBUS DP
Power consumption max.:2 W
Start up torque:0.5 Ncm
Max. number of revolutions:8,192
Housing material:Die-cast aluminum
SET (electronic adjustment):Via PRESET push button or protocol
Status information:LED green (operation), LED red ( bus activity)
Data protocol:Profile for encoders (07hex) - Class 2
Resolution:11 bit x 13 bit
Shaft diameter:16 mm
Resolution power:2,048 x 8,192
Initialization time:1,250 ms
Storage temperature range:-40 °C ... 125 °C, without package
Data transmission rate (baud rate):9.6 kBaud / 12 MBaud / automatic detection
Operating voltage range:10 V ... 32 V
Bus termination:DIP switch
EMC:(according to EN 61000-6-2 and EN 61000-6-3)
Electrical interface:Bus adaptor with 3 x M14 screw fixings
Resistance to shocks:6 g (according to EN 60068-2-27)
Working temperature range:-20 °C ... 80 °C
MTTFd: mean time to dangerous failure:150 a (EN ISO 13849-1)
Address setting:0 ... 127, DIP-switches or protocol
Shaft material:Stainless steel
Permissible relative humidity:98 %

Comments

No comments yet

Write a comment