Sick BCG05-C1QM0199
Wire Draw (Rope) Encoders

Sick BCG05-C1QM0199
  • Measuring lengths of 1.25 m, 3 m, 5 m, and 10 m.
  • Very small dimension (55 ... 190 mm)
  • Modular system: encoder type, measuring length, and interface can be selected
Item Number: BCG05-C1QM0199
904.11
-
+
Total price: 904.11
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Sick BCG05-C1QM0199 is outdated.

Specification:

Part Number1068865
Working temperature range (encoder):-30 °C ... +70 °C
Mass (mechanics):80 g
Part number encoder:1067977
Encoder profile:CiA DS-406, V3.2. - Class C2
Working temperature range (mechanics):-30 °C ... +70 °C
SET (electronic adjustment):Via PRESET push button or protocol
Spring return force:Ca. 1 N ... ca. 1.4 N
Connection type:Universal
Number of steps per revolution:16,384
Measuring wire material:Highly flexible stranded steel 1.4401 stainless steel V4A
Address setting:0 ... 127
Enclosure rating mechanic:IP 50
Protocol:Communication Profile DS 301 V4.02
Power consumption:1.5 W
Wire acceleration:10 m/s?
Supply voltage:10 V ... 30 V
Bus termination:Via external termination resistance
Resistance to vibration:20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
Resistance to shocks:100 g, 6 ms (according to EN 60068-2-27)
Mounted encoder:AHM36 CANopen
Relative humidity / Condensation:90 % (condensation of the optical scanning not permitted)
Linearity:≤ ± 2 mm
Resolution (wire draw + encoder):0.01 mm
EMC:(according to EN 61000-6-2 and EN 61000-6-3)
Encoder:Absolute encoders
Initialization time:2 s
Actual length of cable extension:1.45 m
Mass (including encoder):200 g
Life of wire draw mechanism:1 million cycles
Enclosure rating encoder:IP 66 / IP 67 (according to IEC 60529), housing side, IP 66 / IP 67 (according to IEC 60529), shaft side
Length of wire pulled out per revolution:150 mm
Measuring wire diameter:0.45 mm
MTTFd: mean time to dangerous failure:270 a
Hysteresis:≤ 0.4 mm
Electrical interface:CANopen
Repeatability:≤ 0.2 mm
Part number mechanic:5324019
Operating speed:4 m/s
Working temperature range (combination):Wird definiert durch den h?heren mininalen und niedrigeren maximalen Wert des Arbeitstemperaturbereichs von Encoder und Mechanik
Mass (measuring wire):0.58 g/m
Mounted mechanic:MRA-G055-101D4
Measuring range:0 m ... 1.25 m
Housing material, wire draw mechanism:Plastic, Noryl

Comments

No comments yet

Write a comment