Sick BTF13-P1BM0525
Wire Draw (Rope) Encoders

Sick BTF13-P1BM0525
  • Absolute wire draw encoders
  • Modular measuring system with a wide selection of interfaces/measuring lengths
  • Measuring lengths: 2 m ... 50 m
Item Number: BTF13-P1BM0525
1750.33
-
+
Total price: 1750.33
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1060985
Mounted mechanic:MRA-F130-105D2
Measuring range:0 m ... 5 m
Resistance to vibration:30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
Electrical interface:PROFIBUS
Part number mechanic:6028626
Operating speed:4 m/s
Relative humidity / Condensation:95 % (A3M60, condensation of the optical scanning not permitted), 98 % (ATM60 PROFIBUS, condensation of the optical scanning not permitted)
Initialization time:Ca. 1 s, A3M60, Ca. 12 s, ATM60 PROFIBUS
Linearity:≤ ± 2 mm
Housing material, wire draw mechanism:Aluminum (anodised), plastic
Connection type:Connector 3 x M12, 5-pin, axial
Number of steps per revolution:8,192
Power consumption:1.5 W (A3M60), 2 W (ATM60 PROFIBUS)
Encoder profile:Encoder profile version 1.1 class 1 and class 2 (A3M60), Profil für Encoder (07hex) - Class 2 (ATM60 PROFIBUS)
Address setting:0 ... 127, DIP switch
Enclosure rating mechanic:IP 64
Measuring wire diameter:1.35 mm
Resolution (wire draw + encoder):0.04 mm
Mass (mechanics):2.8 kg
Working temperature range (combination):Wird definiert durch den höheren mininalen und niedrigeren maximalen Wert des Arbeitstemperaturbereichs von Encoder und Mechanik
Length of wire pulled out per revolution:334.1 mm
Measuring wire material:Highly flexible stranded steel 1.4401 stainless steel V4A
EMC:(according to EN 61000-6-2 and EN 61000-6-3)
Part number encoder:1051018
Working temperature range (mechanics):-30 °C ... +70 °C
Protocol:PROFIBUS DP V0 (A3M60), Profil für Encoder (07hex) - Class 2 (ATM60 PROFIBUS)
Supply voltage:10 V ... 32 V
Actual length of cable extension:5.2 m
Mounted encoder:A3M60, ATM60 PROFIBUS
Hysteresis:≤ 2 mm
Bus termination:Via DIP switches
Resistance to shocks:100 g, 6 ms (according to EN 60068-2-27)
Enclosure rating encoder:IP 67
Working temperature range (encoder):-10 °C ... +70 °C, A3M60, -20 °C ... +70 °C, ATM60 PROFIBUS
Mass (measuring wire):7.1 g/m
Wire acceleration:70 m/s²
Spring return force:15 N ... 20 N
MTTFd: mean time to dangerous failure:150 a (ATM60 PROFIBUS), 60 a (A3M60)
Repeatability:≤ 1 mm
Encoder:Absolute encoders
SET (electronic adjustment):Via PRESET push button or protocol
Mass (including encoder):3.08 kg (A3M60), 3.39 kg (A3M60)
Life of wire draw mechanism:1 million cycles

Comments

No comments yet

Write a comment