Sick C4MT-05414ABB03DE0
Light curtains

Sick C4MT-05414ABB03DE0
  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design - sender and receiver in a single housing
Item Number: C4MT-05414ABB03DE0
1251.80
-
+
Total price: 1251.80
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1207103
Integration via Flexi Soft safety controller:CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
TM (mission time):20 a (EN ISO 13849)
Housing cross-section (incl. system connection):15 mm x 32 mm
Permitted cable length:≤ 20 m
Automatic beam coding:+
Synchronization:Optical, without separate synchronization
Scanning range:0 m ... 4 m
Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
Safety integrity level:SIL3 (IEC 61508)
SILCL3 (EN 62061)
Air humidity:15 % ... 95 %, non-condensing
External device monitoring (EDM):+
Type:Type 4 (IEC 61496)
Enclosure rating:IP 65 (EN 60529)
Display elements:LEDs
Cascaded:-
Ambient operating temperature:-20 °C ... +55 °C
Protection class:III (EN 61140)
External device monitoring (delivery status):Deactivated
Performance level:PL e (EN ISO 13849)
Configuration method:Hard wired
PFHd:Standalone system: 4.3  1E-09 (EN ISO 13849)
Connection type:Male connector M12, 5-pin
Typical range:0 m ... 5 m
Resolution:14 mm
Restart interlock (delivery status):Deactivated
Shock resistance:10 g, 16 ms (EN 60068-2-27)
Safe SICK device communication via EFI/SDL:-
Supply voltage:24 V DC (19.2 V DC ... 28.8 V DC)
Switching voltage LOW:2 V DC
Power consumption:≤ 3 A
Switching voltage HIGH:24 V DC (VS - 2.25 V DC ... VS)
Cable length:350 mm
Weight:195 g
Vibration resistance:5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
Protective field height:540 mm
Response time:≤ 14 ms
Housing material:Aluminum alloy ALMGSI 0.5
Ripple:≤ 10 %
Storage temperature:-25 °C ... +70 °C
Category:Category 4 (EN ISO 13849)
Switching current:300 mA
Conductor cross-section:0.34 mm²
Restart interlock:+
Safe state in the event of a fault:At least one OSSD is in the OFF state.
Beam coding:+

Comments

No comments yet

Write a comment