Specification:
Part Number | 1064114 |
DeviceNet: | - |
Ambient operating temperature: | -40 °C ... +50 °C |
Remark (CAN bus): | Depending on sensor connected |
Service plug: | 9-pin D-Sub plug (internal) |
Switching outputs: | 4 (“RES / OUT 1”, “RES / OUT 2”, 2 outputs via optional CMC600: “EXT. OUT 1”, “EXT. OUT 2”) |
Housing: | Polycarbonat |
Weight: | 265 g |
Protection class: | III (EN 60950-1 (2006-04)) |
Supports cloning module (CMC): | Yes |
Storage temperature: | -30 °C ... +75 °C |
Serial (RS-232, RS-422/485): | + |
Enclosure rating: | IP 65 (IEC 60529 (1989-11)) |
CAN bus: | + |
Configuration software: | SOPAS ET |
Scanner connection: | 17-pin M12 socket, A-coded |
PROFIBUS DP: | - |
Switching inputs: | 4 (“SENS / IN 1”, “SENS / IN 2”, 2 inputs via optional CMC600: “EXT. IN 2”, “EXT. IN 2”) |
Brief description: | Connection device basic for connecting one sensor with 2 A fuse, 5 cable glands and RS-232 interface to sensor via M12, 17-pin female connector, all outputs available on screw/spring-loaded terminals, including trigger unit functionality for external ill |
Supports fieldbus gateway (CMF): | No |
Supports display module (CMD): | No |
Optical indicators: | 11 LEDs |
Supported products: | CLV62x - CLV64x (depending on type), CLV69x, Lector®62x, Lector®65x, RFH630, RFU62x, RFU63x |
Supports power supply module (CMP): | No |
Remark (Serial (RS-232, RS-422/485)): | Depending on sensor connected |
Permissible relative humidity: | 90 %, non-condensing |