Sick DML40-2-1211
Distance sensors
- Measurement range from 0.5 m up to 1,200 m with a reflector
- Time-of-flight measurement
- Easy alignment thanks to pilot laser
- Overview
- Comments
The product has been Discontinued by the Manufacturer!
Contact sales manager for a replacement.
Specification:
Part Number | 1027608 |
Data interface: | PROFIBUS DP |
Resolution: | ≤ 1 mm |
Accuracy : | ± 10 mm |
Weight: | Ca. 1,200 g |
Electromagnetic compatibility (EMC): | EN 55011:1998 Kl. B, Gr.1 / EN 6100-6-2:1999 |
Mechanical load: | Shock: IEC 60068-2-27, -2-29 Sine: IEC 60068-2-6 |
Cycle time: | 5,120 per sec. |
Protection class : | III |
Output current IA: | 100 mA |
Enclosure rating: | IP 65 |
Laser class: | 1 (EN 60825-1:Nov.2001, IEC 60825-1:?M2:2001) |
Power consumption : | ≤ 6 W |
Interface for parametrization: | RS-232 |
Switching output : | Q1, Q2 |
Supply voltage Vs: | DC 18 V ... 30 V, limit values |
Measuring range : | 0.5 m ... 1,200 m, on reflector OP60 0.5 m ... 600 m, on reflective tape "Diamond Grade" 0.5 m ... 800 m, on reflector PL880FS01 |
Temperature drift : | Typ. 0.3 mm/K Typ. 0.6 mm/K |
Analog output: | 4 mA ... 20 mA, scalable |
Ripple : | 5 Vpp |
Light source: | Laser, infrared |
Initialization time: | 6 s |
Connection type: | 1 x cable gland, 1 x Sub-D, 9-pin |
Response time : | 1 ms ... 600 ms |
Typ. light spot size (distance): | 20 mm (+ 5 x distance in m) |
Ambient temperature: | Operation with cooling case: -10 ... +75 °C Operation: -10 ... +55 °C Storage: -25 ... +70 °C |
Average depth: | 1/16/64/256/1,024 |
Repeatability : | 6 mm |
Output time: | 1 ms ... 600 ms |
People also buy
Comments
No comments yet