Sick DT500-A212
Long range distance sensors
Long range distance sensors
Item Number:
DT500-A212
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
- Measurement range 0.2 m ... 70 m
- One analog output, RS-422 or CAN
- Highest measurement resolution, repeatability and accuracy without a reflector
Part Number | 1026518 |
Ripple : | 5 Vpp |
Measuring range: | 0.2 m ... 18 m, 6 % remission 0.2 m ... 30 m, 90 % remision |
Initialization time: | 500 ms |
Ambient temperature: | Storage: -25 ... +75 °C Operation with heating: -40 ... +50 °C Operation with cooling case: -40 ... +75 °C |
Output rate: | 250 ms |
Temperature drift: | Typ. 0.05 mm/K |
Repeatability : | 1 mm |
Power consumption: | Typ. 22 W |
Electromagnetic compatibility (EMC): | EN 61000-6-2, EN 55011 / EN 60947-5-7: 2003-9 |
Supply voltage Vs: | DC 10 V ... 30 V, reverse polarity protected, Us ≥ DC 24 V for devices with heating |
Resolution: | ≤ 1 mm |
Data interface: | RS-422 |
Weight: | 1,000 g |
Protection class : | II |
Enclosure rating: | IP 65 |
Laser class: | 2 (EN 60825/21 CFR 1.040) |
Mechanical load: | Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 / -2-29 Sine: EN 600 68-2-6 |
Typ. light spot size (distance): | 10 mm (at 7 m) 100 mm (at 70 m) 45 mm (at 30 m) |
Multifunctional input (MF) : | > 12 V |
Light source : | Laser, red |
Data output: | 20,000 CR LF in mm |
Connection type: | Male connector, M12, 5-pin |
Accuracy : | ± 3 mm |
People also buy
Comments
No comments yet