Sick LFP2000-A4CMB
Level sensors

Sick LFP2000-A4CMB
  • Level sensor for fluids
  • No mechanical moving parts
  • Manually cutable and exchangeable probe with lengths from 200 mm up to 2,000 mm or rope probe up to 4,000 mm
Item Number: LFP2000-A4CMB
785.40
-
+
Total price: 785.40
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1071083
Supply voltage:12 V DC ... 30 V DC
Resolution:< 2 mm
Lower signal level:3.8 mA ... 4 mA
Output current:< 100 mA
Probe type:Mono rod probe
Length coaxial cable:2 m, PVC
Output load:0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 350 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 15 V
Inductive load:< 1 H
CULus certificate:+
Accuracy of sensor element:± 5 mm
Wetted parts:1.4404, PTFE
Signal voltage HIGH:Vs - 2 V
Signal voltage LOW:≤ 2 V
Probe length:2,000 mm
Inactive area at process connector:25 mm
Output signal:1 PNP transistor output (Q1) and 1 PNP / NPN transistor output (Q2) switchable, 4 mA ... 20 mA, 0 V ... 10 V automatic switching depending on the load.
MTTF:194.3 a (EN ISO 13849-1)
Capacitive load:100 nF
Hysteresis:Min. 2 mm, free adjustable
Ambient storage temperature:-40 °C ... +80 °C
Initialization time:≤ 5 s
Upper signal level:20 mA ... 20.5 mA
Connection type:Round connector M12 x 1, 5-pin
Response time:< 400 ms
Maximum level change:500 mm/s
Dielectricity constant:≥ 1.8 with coaxial tube, ≥ 5 for mono rod probe / rope probe
Power consumption:≤ 100 mA at 24 V DC without output load
Measurement:Switch, Continuous
Housing material:Plastic PBT
Protection class:III
Repeatability:≤ 2 mm
Process connection:G ? A
Ambient temperature coaxial cable:-20 °C ... +60 °C
Max.probe load:6 Nm
Inactive area at probe end:10 mm
Temperature drift:< 0.1 mm/K
Process temperature:-20 °C ... +100 °C
Medium:Fluids
Ambient temperature operation:-20 °C ... +60 °C
RoHS certificate:+
IO-Link:+
EMC:EN 61326-1:2006, 2004/108/EG
GOST approval:+
Design:Remote amplifier, cable length 2 m
Conductivity:No limitation
Enclosure rating:IP 67: EN 60529
Process pressure:-1 bar ... 10 bar

Comments

No comments yet

Write a comment