Sick MM12-60A-N-ZC0
Magnetic and Capacitive Sensors
- Detection of magnets
- Operating distances up to 60 mm or more based on the magnet strength
- NAMUR as per EN 60 947-5-6
- Overview
- Comments
The product has been Discontinued by the Manufacturer!
Contact sales manager for a replacement.
Specification:
Part Number | 7900287 |
Electrical wiring: | NAMUR |
Repeatability: | ≤ 1 % |
Magnetic sensitivity: | ≤ 1 mT |
Temperature drift (of Sr): | ± 10 % |
Reverse polarity protection: | + |
Thread size: | M12 x 1 |
Enclosure rating: | IP 67 |
Nominal voltage: | 8.2 V DC |
Input power Pi max.: | 100 mW |
EMC: | According to EN 60947-5-2 |
Cable resistance: | ≤ 50 &;937; |
Switching output: | NAMUR |
Shock/vibration: | 30 g, 11 ms / 10 ... 55 Hz, 1 mm |
Wire-break protection: | 1 |
Ripple: | ≤ 5 % |
Hazardous area category: | 2G |
Current consumption, sensor is not activated: | ≤ 1 mA |
Short-circuit protection: | + |
Housing length: | 62.5 mm |
Input voltage Ui max.: | 16 V |
ATEX marking: | EX II 2G Ex ia IIC T6 Ta: -20 °C ... 70 °C |
Internal capacitance Ci max.: | 15 nF |
Design: | Cylindrical |
Housing material: | Metal, Nickel-plated brass |
Sensing range Sn: | 60 mm |
Hysteresis: | 1 % ... 10 % |
Input current Ii max.: | 30 mA |
Switching frequency: | 5,000 Hz |
Ambient operating temperature: | -25 °C ... 75 °C |
Items supplied: | Fastening nuts (2 x) |
Output characteristic: | Control courrent depending on switching state according to NAMUR EN 60947-5-6 |
Internal inductance Li max.: | 35 µH |
Magnetic alignment: | Axial |
Connection type: | Connector M12, 4-pin |
Tightening torque, max.: | ≤ 7 Nm |
EC Approval Certificate: | T?V 99 ATEX 1398 |
Time delay before availability: | ≤ 2 ms |
Current consumption, sensor is activated: | ≥ 2.5 mA |
Assured sensing range Sa: | 48.6 mm |
People also buy