Sick PFG08-E1CM0371
Wire Draw (Rope) Encoders

Sick PFG08-E1CM0371
  • Measuring lengths of 1.25 m, 3 m, 5 m, and 10 m
  • Very small dimension (55 ... 190 mm)
  • Modular system: encoder type, measuring length, and interface can be selected
Item Number: PFG08-E1CM0371
678.89
-
+
Total price: 678.89
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1060979
Measuring wire material:Highly flexible stranded steel 1.4401 stainless steel V4A
Wire acceleration:10 m/s?
Power consumption:0.7 W
Part number encoder:1037616
Linearity:≤ ± 2 mm
Mounted mechanic:MRA-G080-103D3
Reference signal, number:1, electronically, gated with A and B
Repeatability:≤ 0.2 mm
Resistance to vibration:20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
Resistance to shocks:60 g, 6 ms (according to EN 60068-2-27)
Connection type:Male connector M12, 8-pin, radial
Hysteresis:≤ 0.4 mm
Operating speed:4 m/s
Enclosure rating encoder:IP 67
Mounted encoder:DFS60
Working temperature range (mechanics):-30 °C ... +70 °C
Mass (measuring wire):1.2 g/m
Pulses per revolution:16,384
Electrical interface:HTL/Push pull
Actual length of cable extension:3.2 m
Mass (mechanics):250 g
Length of wire pulled out per revolution:230 mm
Housing material, wire draw mechanism:Plastic, Noryl
Maximum output frequency:600 kHz
Part number mechanic:5322778
Measuring wire diameter:0.55 mm
Supply voltage:4.5 V ... 32 V
Encoder:Incremental encoders
Measuring range:0 m ... 3 m
Working temperature range (combination):Wird definiert durch den h?heren mininalen und niedrigeren maximalen Wert des Arbeitstemperaturbereichs von Encoder und Mechanik
Resolution (wire draw + encoder):0.014 mm
MTTFd: mean time to dangerous failure:300 a
Reference signal, position:Electronically, gated with A and B
Enclosure rating mechanic:IP 50
Working temperature range (encoder):-30 °C ... +70 °C
EMC:(according to EN 61000-6-2 and EN 61000-6-3)
Maximum load current:30 mA
Mass (including encoder):550 g
Life of wire draw mechanism:1 million cycles
Relative humidity / Condensation:90 % (condensation of the optical scanning not permitted)
Spring return force:5 N ... 6.3 N
Initialization time:≤ 32 ms, with mechanical zero pulse width≤ 30 ms

Comments

No comments yet

Write a comment