Sick PHT-RB025ST10S0AMS0Z
Pressure sensor

Sick PHT-RB025ST10S0AMS0Z
PHT-RB025ST10S0AMS0Z art. 6039297
Item Number: PHT-RB025ST10S0AMS0Z
751.88
-
+
Total price: 751.88
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Sick PHT-RB025ST10S0AMS0Z

Datasheet:

  • Article: 6039297
  • Media: Liquid, gaseous
  • Pressure type: Relative pressure
  • Pressure unit: bar
  • Measuring range: 0 bar ... 25 bar
  • Operating temperature: –20 °C ... +150 °C
  • Output signal: 4 mA ... 20 mA , 2-wire
  • EHEDG certified: ?
  • Technical connections: Tri-Clamp 1 Ѕ"
  • Wetted materials: Stainless steel 1.4435
  • Internal transmission fluid: Synthetic oil, FDA compliant
  • Housing material: Stainless steel 1.4571
  • Connection type: Circular plug connector M12 x 1, 4-pin, IP67
  • Supply voltage: 10–30 V DC, 14–30 V DC with 0–10 V output signal, 11 V DC ... 30 V DC with 4 mA ... 20 mA output signal and field housing ,
  • Electrical safety: Overvoltage protection: 36 V DC, Short circuit resistance: QA relative to M, Polarity inversion protection: L+ relative M, Protection class: III,
  • Supply voltage failure: 500 V DC, Supply voltage NEC Class 02 (low voltage and low current max. 100 VA also in emergency condition)
  • EC compliance: EU Electromagnetic Compatibility Directive: 2004/108/EC, EN 61326-2-3
  • Sensor weight: Approx. 500 g
  • Seal: Without seal
  • Protection type: IP67
  • Protection class III: ?
  • Non-linearity: ? ± 0.2 %, span (Best Fit Straight Line, BFSL) according to IEC 61298-2
  • Accuracy: ? ± 0.5% span
  • Measurement repeatability: ? ± 0.1% span
  • Tuning time (10–90%): ? 10 ms
  • Long-term drift/stability per year of operation: ? 0.2% of interval
  • Temperature coefficients in range of nominal temperatures: Average TC of the zero point: ? 0.2% of the span/10 K for measuring ranges from 0–0.6 bar to 0–25 bar, Average TC of the zero point: ? 0.25% of the span/10 K for the range measurement 0–0.4 bar, Average TC of zero point: ? 0.4% of span/10 K for measuring range 0–0.25 bar, Average TC of span ? 0.2% of span/10 K
  • Range of nominal temperatures: 0 °C ... +80 °C
  • Ambient temperature: –20 °C ... +80 °C
  • Storage temperature: –40 ° C ... +100 °C
  • Shock resistance: 500 g according to IEC 60068-2-27 (mechanical shock)
  • Vibration resistance: 15 g according to IEC 60068-2 -6 (vibration at resonance)
  • Pressure unit: bar
  • Category: Sensors pressure
  • Series:PHT
  • Media: gases, liquids
  • Pressure type< /strong>:relative pressure

Comments

No comments yet

Write a comment