Sick UE23-3MF2D2
- Ideal for the connection of emergency stop pushbuttons and safety switches
- 3 safety outputs, 1 application diagnostic output
- Combines the advantages of classic relays and easy circuitry
- Overview
- Comments
Specification:
Part Number | 6034595 |
Width: | 22.5 mm |
Reset/restart: | Manual / automatic / configurable |
Opto-electronic protective devices without RES/EDM: | - |
Maximum power consumption AC: | 3.9 VA |
Connection type: | Screw-type terminals |
Category: | Category 4 (EN ISO 13849) |
Operating voltage DC: | 24 V DC |
Emergency stop pushbuttons: | + |
Electrical life (relay contacts): | 1 1E 06 switching cycles, dependent upon loading, details see operating instructions |
Contact type: | Positively driven |
Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) |
Type of output: | Relay contacts |
Number of enable current contacts: | 3 |
Maximum switching current: | 8 A |
B10d parameter: | 31E 05 switching cycles (AC-15, 230 V, I = 5 A) 2 1E 06 switching cycles (DC-15, 230 V, I = 2 A) 71E 06 switching cycles (DC-13, 24 V, I = 1 A) |
Input circuit: | Single-channel |
System part: | Safety relays |
TM (mission time): | 20 a |
Safety switches: | + |
Enclosure rating: | IP 20 |
Rated operating current (voltage): | 5 A (230 V AC) 360 switching cycles/h 5 A (24 V DC) 3600 switching cycles/h |
Maximum power consumption DC: | 1.9 W |
Number of signalling current contacts: | 1 |
Ambient operating temperature from ... to: | -25 °C ... 55 °C |
Type of switching amplifier: | Main unit |
PFHd: | 3.0 1E-08 |
Performance level: | PL e (EN ISO 13849) |
External device monitoring: | + |
Mechanical life (relay contacts): | 11E 07 switching cycles |
Two-hand control systems: | - |
Stop category: | 0, EN 60204 |
Cross-circuit detection: | - |
Opto-electronic protective devices: | - |
Safety Switch with mechanical lock: | - |
Opto-electronic protective devices with RES/EDM: | - |
Pressure sensitive mats: | - |
People also buy
Comments