Sick i110-E0233
Safety locking device
I110-E0233 SAFETY INTERLOCK art. 6051597
Item Number:
i110-E0233
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Sick i110-E0233
Datasheet:
- Article: 6051597
- Sensor operating principle: Electromechanical
- Locking principle: Normally open circuit principle
- Number of forced opening normally closed (closed) locking control contacts: 2
- Number of normally open locking control contacts: 1
- Number of forced open normally closed (closed) door control contacts: 0
- Number of normally open door monitoring contacts: 0
- Number of normally closed door monitoring contacts: 1
- Holding force Fmax: 2.500 N (EN ISO 14119)
- Holding force FZh: 2.000 N (EN ISO 14119)
- Starter force: ? 35 N
- Holding force: ? 30 N
- Starter frequency: ? 1,200 /h
- Switching directions: 5
- Starting speed: ? 20 m/min
- Value B 10d: 5 x 106 operating cycles
- Design type: Design type 2 (EN ISO 14119)
- Starter coding degree: Low degree coding (EN ISO 14119)
- Safe state in case of error: The switch does not have an internal error detection function and cannot go into a safe state in the event of a fault. Error detection is carried out using a connected safety-oriented logic block.
- Reliable daisy chain: No, individual wiring only (with diagnostics)
- Connection type: Cable entry, 3 x M20
- Pollution degree: 3
- Switching principle: Delayed switch
- Consumption category: AC-15/DC-13 (IEC 60947-5-1)
- Rated operating current (rated operating voltage): 4 A (230 V AC), 4 A (24 V DC),
- Rated insulation voltage Ui: 250 V
- Maximum permissible impulse voltage Uimp: 1.500 V
- Output type: Electromechanical contacts
- Power consumption: ? 8 W
- Short-circuit protection: 4 A gG
- Switching voltage: ? 12 V DC
- Switching current (switching voltage): ? 1 mA ( 24 V DC)
- Magnet duration: 100%
- Locking principle: Normally open circuit principle
- Weight: 0.5 kg
- Housing material: Thermoplastic, glass fiber reinforced
- Actuator head material: Metal
- Mechanical component life: 1 x 106 actuation cycles
- Protection type: IP67 (IEC 60529)
- Operating temperature range: –20 °C ... +55 °C
- Storage temperature: –20 °C ... + 55 °C
- Cable cross-section: 0.34 mmІ ... 1.5 mmІ
- Series:i110 Lock
- Category:Safety locking devices
- Output type:electromechanical contacts
- Connection type< /strong>: cable
- Case material: plastic