Pepperl+Fuchs

Choose a subcategory:

Show all categories

WCS interface module

  • 1-channel
  • Installation in Zone 1, Zone 21, and Class I Div. 1
  • WirelessHART Adapter
  • Battery operated
  • Also supplies field device
  • Input 2-wire HART transmitters and 2-wire HART current sources
  • Output WirelessHART wireless interface
  • Direct mounting on HART or 4 mA ... 20 mA field device
  • Rotatable antenna
  • 1-channel
  • WirelessHART Adapter
  • Battery operated
  • Also supplies field device
  • Input 2-wire HART transmitters and 2-wire HART current sources
  • Output WirelessHART wireless interface
  • Direct mounting on HART or 4 mA ... 20 mA field device
  • Rotatable antenna
  • 1-channel
  • Installation in Zone 1
  • WirelessHART Adapter
  • Battery operated
  • Also supplies field device
  • Input 2-wire HART transmitters and 2-wire HART current sources
  • Output WirelessHART wireless interface
  • Direct mounting on HART or 4 mA ... 20 mA field device
  • Rotatable antenna
  • Installation in Zone 1, 21
  • Installation in Class I, II, Division 1
  • Installation in Class III
  • Ex d housing for Ex d field devices
  • Cast aluminum housing
  • Loop powered
  • Direct mounting on HART or 4 mA ... 20 mA field device
  • Encapsulated antenna
  • Up to 8 field devices in multidrop
  • MODBUS WirelessHART Gateway
  • Graphical network analysis
  • Simple and automatic configuration options
  • Ethernet and RS 485 interface
  • HART and MODBUS protocol via both interfaces
  • Input WirelessHART wireless interface
  • 24 V DC supply
  • Redundant power supply connections
  • EtherNet/IP WirelessHART Gateway
  • Graphical network analysis
  • Simple and automatic configuration options
  • Ethernet and RS 485 interface
  • HART protocol via both interfaces
  • EtherNet/IP protocol via Ethernet interface
  • Input WirelessHART wireless interface
  • 24 V DC supply
  • Redundant power supply connections
  • 2-channel
  • Installation in Zone 1
  • WirelessHART converter
  • Battery operated
  • Thermocouple or RTD input
  • Output WirelessHART wireless interface
  • Internal antenna
Sensing range50 ... 300 mm
Rated ultrasonic frequency400 kHz
Output voltage0 ... 10 V 
  • 316 SS
  • External Mount
  • 20-30VDC
  • M2

Purge &Pressurization

  • Suitable for Zone 1 21 operation, ATEX/IECE certification
  • Manifold combines the digital valve for purging and the needle valve for pressurization in one housing
  • Suitable for steel or plastic tubing
  • Mounting hardware, pneumatic fittings and tubing included

Incremental rotary encoder 

  • Ex e and Ex tb certified
  • Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Stainless Steel
  • Thread NPT 1/2''
  • Seal silicone
  • Packaging unit: 35 pieces, with accessories

Adjustable output 15 ... 30 V/max.1 A

  • Diffuse mode sensor for recording any print mark
  • TEACH-IN, static and dynamic
  • 50 micro-s response time, suitable for extremely rapid scanning processes
  • 3 emitter colors: green, red and blue

Segment Protector F2-SP-IC* F2-SP-IC08.1.03.03.00

Connection plate for HART multiplexer in K system
16-way version

  • Output: 28 ... 30 V/500 mA
  • High-power trunk for high device count and long cable lengths
  • With galvanic isolation
  • Installation in Zone 2/Class I, Div. 2
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Highest efficiency, lowest heat dissipation for highest packing density
  • Hot swappable in redundant configuration
  • Module exchange without tools during operation

This item is out of production!

  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • 2-wire SMART transmitter
  • Output for 4 mA ... 20 mA or 1 V ... 5 V
  • Sink or source mode
  • Line fault detection (LFD)
  • Up to SIL 3 acc. to IEC 61508
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Level sensing input
  • Adjustable range 1 k Omega- ... 150 k Omega-
  • Relay contact output
  • Fault relay contact output
  • Adjustable time delay up to 10 s
  • Minimum/maximum control
  • Line fault detection (LFD)
  • 2-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Current output up to 700 Omega- load
  • HART I/P and valve positioner
  • Line fault detection (LFD)
  • Accuracy 0.05 %
  • Terminal blocks with test sockets
  • Up to SIL 2 acc. to IEC 61508
  • 2-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Usable as signal splitter (1 input and 2 outputs)
  • 2 x 2 relay contact outputs with AND logic
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc. to IEC 61508
  • 2-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Input 2-wire SMART transmitters
  • Output 0/4 mA ... 20 mA current sink
  • Terminal blocks with test sockets
  • Up to SIL 2 acc. to IEC 61508
  • electronic insert FEM22 (E5)
  • electronic insert FEM24 (WA)
Maximum DC Voltage30V
Response time0.5 ms
Maximum Current≤35 mA
  • 8 segments, redundant, individual modules per segment
  • Supports all PLC and PCS hosts, redundant terminals
  • High-power trunk: Live work on devices in any hazardous area
  • Best quality, smallest size and lowest heat dissipation
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Optional advanced diagnostics
  • Passive impedance for high reliability
  • Supports Ex ic voltage limitation
  • Installation in Zone 2/Div. 2