Pepperl+Fuchs
Choose a subcategory:
Show all categories
Vision Sensor
WCS interface module
- 1-channel
- Installation in Zone 1, Zone 21, and Class I Div. 1
- WirelessHART Adapter
- Battery operated
- Also supplies field device
- Input 2-wire HART transmitters and 2-wire HART current sources
- Output WirelessHART wireless interface
- Direct mounting on HART or 4 mA ... 20 mA field device
- Rotatable antenna
- 1-channel
- WirelessHART Adapter
- Battery operated
- Also supplies field device
- Input 2-wire HART transmitters and 2-wire HART current sources
- Output WirelessHART wireless interface
- Direct mounting on HART or 4 mA ... 20 mA field device
- Rotatable antenna
- 1-channel
- Installation in Zone 1
- WirelessHART Adapter
- Battery operated
- Also supplies field device
- Input 2-wire HART transmitters and 2-wire HART current sources
- Output WirelessHART wireless interface
- Direct mounting on HART or 4 mA ... 20 mA field device
- Rotatable antenna
- Installation in Zone 1, 21
- Installation in Class I, II, Division 1
- Installation in Class III
- Ex d housing for Ex d field devices
- Cast aluminum housing
- Loop powered
- Direct mounting on HART or 4 mA ... 20 mA field device
- Encapsulated antenna
- Up to 8 field devices in multidrop
- MODBUS WirelessHART Gateway
- Graphical network analysis
- Simple and automatic configuration options
- Ethernet and RS 485 interface
- HART and MODBUS protocol via both interfaces
- Input WirelessHART wireless interface
- 24 V DC supply
- Redundant power supply connections
- EtherNet/IP WirelessHART Gateway
- Graphical network analysis
- Simple and automatic configuration options
- Ethernet and RS 485 interface
- HART protocol via both interfaces
- EtherNet/IP protocol via Ethernet interface
- Input WirelessHART wireless interface
- 24 V DC supply
- Redundant power supply connections
- 2-channel
- Installation in Zone 1
- WirelessHART converter
- Battery operated
- Thermocouple or RTD input
- Output WirelessHART wireless interface
- Internal antenna
Sensing range | 50 ... 300 mm |
Rated ultrasonic frequency | 400 kHz |
Output voltage | 0 ... 10 V |
- 316 SS
- External Mount
- 20-30VDC
- M2
Purge &Pressurization
- Suitable for Zone 1 21 operation, ATEX/IECE certification
- Manifold combines the digital valve for purging and the needle valve for pressurization in one housing
- Suitable for steel or plastic tubing
- Mounting hardware, pneumatic fittings and tubing included
Incremental rotary encoder
- Ex e and Ex tb certified
- Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22
- Stainless Steel
- Thread NPT 1/2''
- Seal silicone
- Packaging unit: 35 pieces, with accessories
Adjustable output 15 ... 30 V/max.1 A
- Diffuse mode sensor for recording any print mark
- TEACH-IN, static and dynamic
- 50 micro-s response time, suitable for extremely rapid scanning processes
- 3 emitter colors: green, red and blue
Segment Protector F2-SP-IC* F2-SP-IC08.1.03.03.00
Connection plate for HART multiplexer in K system
16-way version
- Output: 28 ... 30 V/500 mA
- High-power trunk for high device count and long cable lengths
- With galvanic isolation
- Installation in Zone 2/Class I, Div. 2
- For FOUNDATION Fieldbus H1 and PROFIBUS PA
- Highest efficiency, lowest heat dissipation for highest packing density
- Hot swappable in redundant configuration
- Module exchange without tools during operation
This item is out of production!
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- 2-wire SMART transmitter
- Output for 4 mA ... 20 mA or 1 V ... 5 V
- Sink or source mode
- Line fault detection (LFD)
- Up to SIL 3 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (Power Rail)
- Level sensing input
- Adjustable range 1 k Omega- ... 150 k Omega-
- Relay contact output
- Fault relay contact output
- Adjustable time delay up to 10 s
- Minimum/maximum control
- Line fault detection (LFD)
- 2-channel signal conditioner
- 24 V DC supply (Power Rail)
- Current output up to 700 Omega- load
- HART I/P and valve positioner
- Line fault detection (LFD)
- Accuracy 0.05 %
- Terminal blocks with test sockets
- Up to SIL 2 acc. to IEC 61508
- 2-channel isolated barrier
- 24 V DC supply (Power Rail)
- Dry contact or NAMUR inputs
- Usable as signal splitter (1 input and 2 outputs)
- 2 x 2 relay contact outputs with AND logic
- Line fault detection (LFD)
- Reversible mode of operation
- Up to SIL 2 acc. to IEC 61508
- 2-channel isolated barrier
- 24 V DC supply (Power Rail)
- Input 2-wire SMART transmitters
- Output 0/4 mA ... 20 mA current sink
- Terminal blocks with test sockets
- Up to SIL 2 acc. to IEC 61508
- electronic insert FEM22 (E5)
- electronic insert FEM24 (WA)
Maximum DC Voltage | 30V |
Response time | 0.5 ms |
Maximum Current | ≤35 mA |
- 8 segments, redundant, individual modules per segment
- Supports all PLC and PCS hosts, redundant terminals
- High-power trunk: Live work on devices in any hazardous area
- Best quality, smallest size and lowest heat dissipation
- For FOUNDATION Fieldbus H1 and PROFIBUS PA
- Optional advanced diagnostics
- Passive impedance for high reliability
- Supports Ex ic voltage limitation
- Installation in Zone 2/Div. 2