Pepperl+Fuchs

Choose a subcategory:
Show all categories
  • 24 V AC/DC supply
  • (6) Monitored inputs
  • DIN rail mountable
  • Dual output relay contacts
  • Internal relay monitoring
  • Removable screw terminals
  • 1-channel isolated barrier
  • 115 V AC supply
  • Dry contact or NAMUR inputs
  • Input frequency 1 mHz ... 5 kHz
  • 2 relay contact outputs
  • Start-up override
  • Configurable by keypad
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
  • 2-channel isolated barrier
  • 115 V AC supply
  • Dry contact or NAMUR inputs
  • Passive transistor output, non-polarized
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc. to IEC 61508
  • 1-channel isolated barrier
  • 115 V AC supply
  • Dry contact or NAMUR inputs
  • Relay contact output
  • Fault relay contact output
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
  • 2-channel isolated barrier
  • 115 V AC supply
  • Dry contact or NAMUR inputs
  • Latching relay contact output
  • Line fault detection (LFD)

kfa6

  • Operating temperature range: from -40 to 85 °C
  • Weight: from 0.1 to 0.5 kg
  • Sizes: from 50 to 120 mm
  • Power supply: 230 V AC, 24 V DC
  • 1-channel isolated barrier
  • 230 V AC supply
  • Dry contact or NAMUR inputs
  • Relay contact and transistor output
  • Adjustable output timer functions from 10 ms ... 60 min
  • Input frequency up to 80 Hz- pulse divider up to 1 kHz
  • Reset function
  • Configurable by keypad
  • Line fault detection (LFD)
  • 1-channel isolated barrier
  • 230 V AC supply
  • Dry contact or NAMUR inputs
  • Input frequency 1 mHz ... 5 kHz
  • 2 relay contact outputs
  • Start-up override
  • Configurable by keypad
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
  • 1-channel signal conditioner
  • 230 V AC supply
  • Level sensing input
  • Adjustable range 1 k Omega- ... 30 k Omega-
  • Relay contact output
  • Minimum/maximum control
  • 1-channel signal conditioner
  • 230 V AC supply
  • Level sensing input
  • Adjustable range 5 k Omega- ... 150 k Omega-
  • Relay contact output
  • Minimum/maximum control
  • 1-channel signal conditioner
  • 230 V AC supply
  • Level sensing input
  • Adjustable range 1 k Omega- ... 150 k Omega-
  • Relay contact output
  • Fault relay contact output
  • Adjustable time delay up to 10 s
  • Minimum/maximum control
  • Line fault detection (LFD)
  • 2-channel signal conditioner
  • 230 V AC supply
  • Level sensing input
  • Adjustable range 1 k Omega- ... 150 k Omega-
  • Relay contact output
  • Adjustable time delay up to 10 s
  • Minimum/maximum control
  • Line fault detection (LFD)
  • 1-channel isolated barrier
  • 230 V AC supply
  • Level sensing input
  • Adjustable range 1 k Omega- ... 150 k Omega-
  • Relay contact output
  • Fault relay contact output
  • Adjustable time delay up to 10 s
  • Minimum/maximum control
  • Line fault detection (LFD)
  • 2-channel isolated barrier
  • 230 V AC supply
  • Dry contact or NAMUR inputs
  • Passive transistor output, non-polarized
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc. to IEC 61508
  • 2-channel signal conditioner
  • 115/230 V AC supply
  • 3-wire PNP/NPN sensor or push-pull input
  • Relay contact output
  • DIP switch selectable functions
  • Minimum/maximum control
  • Up to SIL 2 acc. to IEC 61508
  • 2-channel
  • 115/230 V AC supply
  • 3-wire PNP/NPN sensor or push-pull input
  • Relay contact output
  • DIP switch selectable functions
  • Minimum/maximum control
  • Up to SIL 2 acc. to IEC 61508
  • 1-channel isolated barrier
  • 230 V AC supply
  • Dry contact or NAMUR inputs
  • Relay contact output
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
  • 1-channel isolated barrier
  • 230 V AC supply
  • Dry contact or NAMUR inputs
  • Relay contact output
  • Fault relay contact output
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
  • 2-channel isolated barrier
  • 230 V AC supply
  • Dry contact or NAMUR inputs
  • Relay contact output
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
Switch amplifier
Switch amplifier
  • 2-channel isolated barrier
  • 230 V AC supply
  • Dry contact or NAMUR inputs
  • Latching relay contact output
  • Line fault detection (LFD)
  • 115/230 V AC supply
  • Output 24 V DC, 500 mA
  • Electronic short circuit protection
  • Power Rail connection

kfd0

  • Level of protection against current leakage: 10 μA, 50 Hz
  • Compliance with standards: ATEX, IECEx, SIL 3
  • Operating temperature: -20 ... 60 °C
  • Operating humidity: Up to 95% without condensation
  • Degree of protection of the housing: IP20
  • 1-channel signal conditioner
  • 24 V DC supply (loop powered)
  • Current or voltage input
  • Output: 4 ... 20 mA
  • Potentiometer or DIP switch selectable ranges
  • Line fault detection (LFD)
  • 1-channel signal conditioner
  • 24 V DC supply (loop powered)
  • Current input/output 4 mA ... 20 mA
  • transmitter power supply
  • Accuracy 0.1 %
  • Reverse polarity protection
  • Up to SIL 2 acc. to IEC 61508