kfu8

  • Accuracy: ±0.5% of the original value
  • Stability: ±0.02% per hour
  • Reaction time: 10 ms
  • Spectral range: 0 - 200 kHz
  • Current consumption: 20 mA
  • Temperature range: -40...+70 °C
  • Humidity: 95% at 40 °C
  • 1-channel signal conditioner
  • Universal usage at different power supplies
  • Input 2-wire and 3-wire transmitters and 2-wire current sources
  • Output 0/4 mA ... 20 mA
  • 2 relay contact outputs
  • Adjustable energized/de-energized delay
  • Programmable high/low alarm
  • Linearization function (max 20 points)
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
  • 1-channel isolated barrier
  • Universal usage at different power supplies
  • Input 2-wire and 3-wire transmitters and 2-wire current sources
  • Output 0/4 mA ... 20 mA
  • 2 relay contact outputs
  • Adjustable energized/de-energized delay
  • Programmable high/low alarm
  • Linearization function (max 20 points)
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
  • Speed monitoring up to 40 kHz
  • 1 pre-select value with relay output and LED indicator
  • 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder connectable
  • Start-up delay
  • Menu driven operation via 4 front keys
  • Period measurement
  • Output signal can be inverted
  • Display devices can be set between 0.1 ... 2.5 sec.
  • 1-channel signal conditioner
  • Universal usage at different power supplies
  • Dry contact or NAMUR inputs
  • Input frequency 1 mHz ... 12 kHz
  • 2 relay contact outputs
  • Start-up override
  • Configurable by keypad
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
  • Limit frequency 40 kHz
  • Voltage or current ouptput
  • Incrementing output
    (Spacing factor 1 ... 9999)
  • Multi-range power pack
  • 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder connectable
  • Auxiliary power output for sensors
  • Connection via Power Rail
  • Period measurement
  • Display: Input in Hz or 1/min, output in V or mA
  • adjustable updating of indication (0,001 ... 2,5 s)
  • Limit frequency 40 kHz
  • Voltage or current ouptput
  • Incrementing output
    (Spacing factor 1 ... 9999)
  • 2-, 3-, 4-wire sensors and rotary encoder can be connected
  • Auxiliary power output for sensors
  • Connection via Power Rail
  • Period measurement
  • Display: Input in Hz or 1/min, output in V or mA
  • adjustable updating of indication (0,001 ... 2,5 s)
  • 1-channel isolated barrier
  • Universal usage at different power supplies
  • Thermocouple, RTD, potentiometer or voltage input
  • Redundant TC input
  • Current output 0/4 mA ... 20 mA
  • 2 relay contact outputs
  • Configurable by PACTware or keypad
  • Line fault (LFD) and sensor burnout detection
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
  • 1-channel signal conditioner
  • Universal usage at different power supplies
  • 3-wire PNP/NPN sensor or push-pull input
  • 2 relay contact outputs
  • Adjustable energized/de-energized delay
  • 1-channel isolated barrier
  • Universal usage at different power supplies
  • Input for NAMUR sensors or dry contacts
  • Input frequency 1 mHz ... 5 kHz
  • Current output 0/4 mA ... 20 mA
  • Relay contact and transistor output
  • Start-up override
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
  • 2-channel signal conditioner
  • Universal usage at different power supplies
  • Dry contact or NAMUR inputs
  • Input frequency 1 mHz ... 1 kHz
  • Current output 0/4 mA ... 20 mA
  • Relay contact and transistor output
  • Start-up override
  • Configurable by PACTware or keypad
  • Line fault detection (LFD)
  • 2-channel isolated barrier
  • Universal usage at different power supplies
  • Dry contact or NAMUR inputs
  • Input frequency 1 mHz ... 1 kHz
  • Current output 0/4 mA ... 20 mA
  • Relay contact and transistor output
  • Start-up override
  • Configurable by PACTware or keypad
  • Line fault detection (LFD)
  • 1-channel signal conditioner
  • Universal usage at different power supplies
  • Scaleable current or voltage input
  • Current or voltage output
  • Relay contact output
  • Configurable by keypad
  • Line fault detection (LFD)
  • 1-channel signal conditioner
  • Universal usage at different power supplies
  • Input 2-wire and 3-wire transmitters, current and voltage sources
  • Current and voltage output
  • 1-channel isolated barrier
  • 115/230 V AC supply
  • Input for approved dry contacts or SN/S1N sensors
  • Relay contact output
  • Fault indication output
  • Line fault detection (LFD)
  • Up to SIL 3 acc. to IEC 61508
  • Up to PL d acc. to EN/ISO 13849
  • High temperature resistance
  • Side light outlet enables installation when space is at a premium
  • Series voltage reducing module
  • Removable terminals
  • Polarity reversal protected
  • Installation in cabinet on DIN mounting rail
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Output: 14.7 ... 30.7 V/1 A
  • For very high segment load
  • High-power trunk for high device count and long cable lengths
  • Installation only in safe areas
  • For FOUNDATION Fieldbus H1
  • Selectable, high-availability terminator
  • Low heat dissipation
  • Supply via Power Rail
  • Thread M2.6 / M4
  • Screw fitting offset lens available
  • Thread M2.6
  • Screw fitting offset lens available
  • Thread M3
  • High detection ranges achievable
  • Thread M6
  • Bendable tip
  • High detection ranges achievable
  • Thread M6
  • Coaxial
  • Thread M4 / M2.6
  • Coaxial
  • Thread M3