Siemens Pressure sensors SITRANS P

Choose a subcategory:
Show all categories
SITRANS P220 TRANSMITTERS FOR PRESSURE AND ABSOLUTE PRESSURE FULLY WELDED VERSION FOR HIGH-PRESSURE AND REFRIGERANT APPLICATIONS NON-LINEARITY: 0,25 PERCENT (TYPICALLY) WETTED PARTS MATERIAL: STAINLESS STEEL, NON-WETTED PARTS MATERIAL: STAINLESS STEEL MEASURING RANGE FOR GAUGE: 0 TO 400 BAR, OVERLOAD- PRESSURE 1000 BAR OUTPUT SIGNAL: 4 TO 20 MA TWO-WIRE CONNECTION, POWER SUPPLY DC 7 TO 33 V WITHOUT EXPLOSION PROTECTION ELECTRICAL CONNECTION: PLUG TO DIN EN 175301-803-A, THREAT FOR PACKED GLAND M16 (WITH CONNECTOR) PROCESS CONNECTION: G1/2", MALE TO EN 837-1 (1/2", BSP MALE) (STANDARD FOR METRIC PRESSURE RANGES MBAR, BAR) - STANDARD VERSION
SITRANS P220 TRANSMITTERS FOR PRESSURE AND ABSOLUTE PRESSURE FULLY WELDED VERSION FOR HIGH-PRESSURE AND REFRIGERANT APPLICATIONS NON-LINEARITY: 0,25 PERCENT (TYPICALLY) WETTED PARTS MATERIAL: STAINLESS STEEL, NON-WETTED PARTS MATERIAL: STAINLESS STEEL MEASURING RANGE FOR GAUGE: 0 TO 400 BAR, OVERLOAD- PRESSURE 1000 BAR OUTPUT SIGNAL: 0 TO 10 V, THREE-WIRE CONNECTION, POWER SUPPLY DC 12 TO 33 V WITHOUT EXPLOSION PROTECTION ELECTRICAL CONNECTION: PLUG TO DIN EN 175301-803-A, THREAT FOR PACKED GLAND M16 (WITH CONNECTOR) PROCESS CONNECTION: G1/2", MALE TO EN 837-1 (1/2", BSP MALE) (STANDARD FOR METRIC PRESSURE RANGES MBAR, BAR) - STANDARD VERSION
SITRANS P220 TRANSMITTERS FOR PRESSURE AND ABSOLUTE PRESSURE FULLY WELDED VERSION FOR HIGH-PRESSURE AND REFRIGERANT APPLICATIONS NON-LINEARITY: 0,25 PERCENT (TYPICALLY) WETTED PARTS MATERIAL: STAINLESS STEEL, NON-WETTED PARTS MATERIAL: STAINLESS STEEL MEASURING RANGE FOR GAUGE: 0 TO 600 BAR, OVERLOAD- PRESSURE 1500 BAR OUTPUT SIGNAL: 4 TO 20 MA TWO-WIRE CONNECTION, POWER SUPPLY DC 7 TO 33 V WITHOUT EXPLOSION PROTECTION ELECTRICAL CONNECTION: PLUG TO DIN EN 175301-803-A, THREAT FOR PACKED GLAND M16 (WITH CONNECTOR) PROCESS CONNECTION: G1/2", MALE TO EN 837-1 (1/2", BSP MALE) (STANDARD FOR METRIC PRESSURE RANGES MBAR, BAR) - STANDARD VERSION
TRANSMITTERS SITRANS LH100 FOR HYDROSTATIC LEVEL MEASUREMENT, SUBMERSIBLE TRANSMITTER, TWO-WIRE CONNECTION, 4...20 MA HOUSING MATERIAL 316L (1.4404) MEASURING CELL CERAMICS (96%) WITH FIXED MOUNTED LD-PE CABLE MEASURING RANGE: 0 - 6 MH2O CABLE LENGHT: 10 M . SEALING MATERIAL BETWEEN SENSOR AND HOUSING: FPM (STANDARD) WITH ATEX II1 G EX IA IIC T4 GA AND IECEX EX IA IIC T4 GA

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART,4-20 MA TRANSMITTER FOR PRESSURE MEASURING CELL FILLING SILICONE OIL, NORMAL CLEuropean Article NumberING SPAN: 0,01 ... 1 BAR G (0.15 ... 14.5 PSI G), OVERLOAD LIMIT 6 BAR DIAPHRAGM STAINLESS STEEL, MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: FEMALE THREAD 1/2-14 NPT DIE-CAST ALUMINIUM HOUSING STANDARD DESIGN WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND 1/2-14 NPT HOUSING COVER WITH WINDOW

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART,4-20 MA TRANSMITTER FOR PRESSURE MEASURING CELL FILLING SILICONE OIL, NORMAL CLEuropean Article NumberING SPAN: 0,01 ... 1 BAR G (0.15 ... 14.5 PSI G), OVERLOAD LIMIT 6 BAR DIAPHRAGM STAINLESS STEEL, MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: FEMALE THREAD 1/2-14 NPT DIE-CAST ALUMINIUM HOUSING STANDARD DESIGN EXPLOSION PROTECTION EEX IA ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X 1.5 HOUSING COVER WITH WINDOW

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART,4-20 MA TRANSMITTER FOR PRESSURE MEASURING CELL FILLING SILICONE OIL, NORMAL CLEuropean Article NumberING SPAN: 0,01 ... 1 BAR G (0.15 ... 14.5 PSI G), OVERLOAD LIMIT 6 BAR DIAPHRAGM STAINLESS STEEL, MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: MALE THREAD 1/2-14NPT DIE-CAST ALUMINIUM HOUSING STANDARD DESIGN WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND 1/2-14 NPT HOUSING COVER WITH WINDOW

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART,4-20 MA TRANSMITTER FOR PRESSURE MEASURING CELL FILLING SILICONE OIL, NORMAL CLEuropean Article NumberING SPAN: 0,16 ... 16 BAR G (2.32 ... 232 PSI G), OVERLOAD LIMIT 32 BAR DIAPHRAGM STAINLESS STEEL, MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: MALE THREAD 1/2-14NPT DIE-CAST ALUMINIUM HOUSING STANDARD DESIGN WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND 1/2-14 NPT HOUSING COVER WITH WINDOW

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART,4-20 MA TRANSMITTER FOR PRESSURE MEASURING CELL FILLING SILICONE OIL, NORMAL CLEuropean Article NumberING SPAN: 4,0 ... 400 BAR G (58.0 ... 5802 PSI G), OVERLOAD LIMIT 600 BAR DIAPHRAGM STAINLESS STEEL, MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: CONNECTION SHANK G1/2 B TO EN 837-1 DIE-CAST ALUMINIUM HOUSING INTERNATIONAL DESIGN ENGLISH INSCRIPTION AND DOCUMENTATION AS CD WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X 1.5 WITHOUT VISIBLE DIGITAL INDICATOR (DIGITAL DISPLAY HIDDEN, SETTING: MA)

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III PROFIBUS PA, TRANSMITTER FOR PRESSURE MEASURING CELL FILLING SILICONE OIL, NORMAL CLEuropean Article NumberING NOMINAL MEASURING RANGE 1 BAR G (14.5 PSI G), OVERLOAD LIMIT 6 BAR DIAPHRAGM STAINLESS STEEL, MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: MALE THREAD 1/2-14NPT DIE-CAST ALUMINIUM HOUSING INTERNATIONAL VERSION ENGLISH INSCRIPTION AND DOCUMENTATION ON CD WITHOUT EXPLOSION PROTECTION ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND 1/2-14 NPT WITHOUT VISIBLE DIGITAL INDICATOR (DIGITAL DISPLAY HIDDEN, SETTING: MA)

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III / P410, PROFIBUS PA, transmitter

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 160 (MWP 2320 PSI): 2,5 TO 250 MBAR (1.004 TO 100.4 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: M10 DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL STANDARD DESIGN . WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X1.5 WITHOUT VISIBLE DIGITAL INDICATOR (DIGITAL DISPLAY HIDDEN, SETTING: MA)

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 160 (MWP 2320 PSI): 2,5 TO 250 MBAR (1.004 TO 100.4 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: M10 DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL INTERNATIONAL DESIGN ENGLISH INSCRIPTION DOCUMENTATION AS CD WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X1.5 WITHOUT VISIBLE DIGITAL INDICATOR (DIGITAL DISPLAY HIDDEN, SETTING: MA)

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 160 (MWP 2320 PSI): 2,5 TO 250 MBAR (1.004 TO 100.4 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: 7/16-20 UNF DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL STANDARD DESIGN . WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND 1/2-14 NPT HOUSING COVER WITH WINDOW

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 160 (MWP 2320 PSI): 2,5 TO 250 MBAR (1.004 TO 100.4 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: 7/16-20 UNF DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL INTERNATIONAL DESIGN ENGLISH INSCRIPTION DOCUMENTATION AS CD WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X1.5 HOUSING COVER WITH WINDOW

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 160 (MWP 2320 PSI): 6 TO 600 MBAR (2.409 TO 240.9 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: M10 DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL STANDARD DESIGN . WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND 1/2-14 NPT WITHOUT VISIBLE DIGITAL INDICATOR (DIGITAL DISPLAY HIDDEN, SETTING: MA)

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 160 (MWP 2320 PSI): 6 TO 600 MBAR (2.409 TO 240.9 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: 7/16-20 UNF DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL STANDARD DESIGN . WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND 1/2-14 NPT HOUSING COVER WITH WINDOW

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 160 (MWP 2320 PSI): 16 TO 1600 MBAR (6.424 TO 642.4 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: 7/16-20 UNF DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL STANDARD DESIGN . WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND 1/2-14 NPT HOUSING COVER WITH WINDOW

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 160 (MWP 2320 PSI): 16 TO 1600 MBAR (6.424 TO 642.4 INH2O), MAX. STATIC PRESSURE 160 BAR DESIGN FOR REMOTE SEALS. NOTE: PLEASE ADD THE DELIVERY TIME OF THE REMOTE SEAL! PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: 7/16-20 UNF DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL STANDARD DESIGN . WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X1.5 HOUSING COVER WITH WINDOW

The Product is not Available now!

Check the Price with the manager.

SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEuropean Article NumberING SPAN: PN 160 (MWP 2320 PSI): 50 TO 5000 MBAR (20.08 TO 2008 INH2O), MAX. STATIC PRESSURE 160 BAR DIAPHRAGM STAINLESS STEEL PARTS OF MEASURING CELL STAINLESS STEEL PROCESS CONNECTION: 1/4-18 NPT MOUNTING THREAD: M10 DIE-CAST ALUMINIUM HOUSING, PROCESS FLANGE BOLTS STAINLESS STEEL INTERNATIONAL DESIGN ENGLISH INSCRIPTION DOCUMENTATION AS CD WITHOUT EXPLOSION PROTECTION, ELECTRIC CONNECTION AND CABLE INLET: CABLE GLAND M20 X1.5 HOUSING COVER WITH WINDOW
DIAPHRAGM SEAL DIRECTLY MOUNTED TYPE 7MF4912, . PRESSURE EQUIPMENT DIRECTIVE F GAS 1/LIQUIDS 1 ART. 3.3 SEP DIRECTLY MOUNTED ON SITRANS P TRANSMITTER FOR LEVEL, DS SERIES, PROCESS CONNECTION ACC. EN 1092-1 / ASME B16.5 NOM. DIAMETER, NOM. PRESSURE: DN 80, PN 40 WETTED PARTS: STAINLESS STEEL, WITHOUT FOIL, EXTENSION 0 MM TRANSMISSION FLUID: SILICON OIL M5
DIAPHRAGM SEAL DIRECTLY MOUNTED TYPE 7MF4912, . PRESSURE EQUIPMENT DIRECTIVE F GAS 1/LIQUIDS 1 ART. 3.3 SEP DIRECTLY MOUNTED ON SITRANS P TRANSMITTER FOR LEVEL, DS SERIES, PROCESS CONNECTION ACC. EN 1092-1 / ASME B16.5 NOM. DIAMETER, NOM. PRESSURE: 3 INCH, CLASS 150 WETTED PARTS: STAINLESS STEEL, WITHOUT FOIL, EXTENSION 0 MM TRANSMISSION FLUID: SILICON OIL M5
COVER (DIE-CAST ALUMINIUM) WITH WINDOW INCL.O-RING FOR SERIES SITRANS P DSIII, DSIII PA AND DSIII FF
SITRANS P TRANSMITTER COMPACT FOR PRESSURE AND ABSOLUT PRESSURE FOR FOOD, PHARMACEU- TICALS AND BIOTECHNOLOGY, WITH DIAPHRAGM FLUSH AT FRONT. 2-WIRE SYSTEM, PROCESS TEMPERA- TURE UP TO 140 DEG. CEL., ACCURACY 0.2 % OF F.S.V. OUTPUT SIGNAL: 4...20 MA, PROCESS CONNECTION: QUICK-RELEASE CONNECTION: CLAMP CONNECTION ACCORDING ISO 2852: 1 INCH FILLING LIQUID: LIQUID FDA APPROVED OUTPUT SIGNAL : 4-20 MA HOUSING(STAINLESS STEEL1.4404)/ ELECTRICAL CONNECTION: FIELD HOUSING STAINLESS STEEL WITH CABLE GLAND, IP67 MEASURING RANGE: 0...1 BAR OVERLOAD PRESSURE: 10 BAR WITHOUT EXPLOSION PROTECTION
SITRANS P TRANSMITTER COMPACT FOR PRESSURE AND ABSOLUT PRESSURE FOR FOOD, PHARMACEU- TICALS AND BIOTECHNOLOGY, WITH DIAPHRAGM FLUSH AT FRONT. 2-WIRE SYSTEM, PROCESS TEMPERA- TURE UP TO 140 DEG. CEL., ACCURACY 0.2 % OF F.S.V. OUTPUT SIGNAL: 4...20 MA, PROCESS CONNECTION: QUICK-RELEASE CONNECTION: SMS-NORM WITH SCREW NECKS: 1 INCH FILLING LIQUID: LIQUID FDA APPROVED OUTPUT SIGNAL : 4-20 MA HOUSING(STAINLESS STEEL1.4404)/ ELECTRICAL CONNECTION: HOUSING WITH ANGELD PLUG ACCORDING DIN 43650, IP65 MEASURING RANGE: 0...1 BAR OVERLOAD PRESSURE: 10 BAR WITHOUT EXPLOSION PROTECTION

DOUBLE SHUT-OFF COCK DN 5 MAT. NO. 1.4404, MAX. OPERATING PRESSURE 420 BAR PRESSURE EQUIPMENT DIREKTIVE F. GAS 1/LIQUIDS 1 ART. 3.3 SEP

DOUBLE SHUT-OFF COCK DN 5 (SLEEVE - JOURNAL), MAT. NO. 1.4404, MAX. OPERATING PRESSURE 420 BAR PRESSURE EQUIPMENT DIREKTIVE F. GAS 1/LIQUIDS 1 ART. 3.3 SEP
DOUBLE SHUT-OFF COCK DN 5 (JOURNAL - JOURNAL), MAT. NO. 1.4404, MAX. OPERATING PRESSURE 420 BAR PRESSURE EQUIPMENT DIREKTIVE F. GAS 1/LIQUIDS 1 ART. 3.3 SEP
DOUBLE SHUT-OFF COCK DN 5 (SLEEVE - SLEEVE), MAT.NO. 1.4404, MAX. OPERATING PRESSURE 420 BAR PRESSURE EQUIPMENT DIREKTIVE FOR GAS 1/LIQUIDS 1 ART. 3.3 SEP
DOUBLE SHUT-OFF COCK DN 5 (COLLAR - SLEEVE), MAT. NO. 1.4404, MAX. OPERATING PRESSURE 420 BAR PRESSURE EQUIPMENT DIREKTIVE FOR GAS 1/LIQUIDS 1 ART. 3.3 SEP