IFM Electronic AS-Interface AirBoxes for pneumatics


AS-i AirBox, AS-i interface to FC and SC lower parts, 2 inputs / 2 outputs, 2 digital inputs, Sockets M12 x 1, 2 pneumatic outputs

AS-i AirBox, AS-i interface to FC and SC lower parts, 2 inputs / 2 outputs, Connection to the pneumatic system by tube fittings, 2 digital inputs, Sockets M12 x 1, 2 pneumatic outputs

AS-i AirBox, AS-i interface to FC-E lower parts, 2 x 2 inputs / 2 outputs, Connection to the pneumatic system by tube fittings, 2 x 2 digital inputs, Sockets M12 x 1, 2 pneumatic outputs

AS-i AirBox, AS-i interface to FC lower parts, 2 x 2 inputs / 2 outputs, Connection to the pneumatic system by tube fittings, 2 x 2 digital inputs, Sockets M12 x 1, 2 pneumatic outputs

AS-i AirBox, AS-i interface to FC lower parts, 2 inputs / 1 output NO/NC selectable (monostable), Connection to the pneumatic system by tube fittings, 1 x 2 or 2 x 1 digital inputs, Sockets M12 x 1, 1 pneumatic output (NO/NC selectable)

AS-i AirBox, AS-i interface to FC-E lower parts, 2 inputs / 1 output NO/NC selectable (monostable), Connection to the pneumatic system by tube fittings, Sockets M12 x 1, 1 pneumatic output (NO/NC selectable)

AS-i AirBox, AS-i interface to FC lower parts, 2 x 2 inputs / 2 outputs, Connection to the pneumatic system by tube fittings, Manual override by pressing/releasing or pressing/turning/locking, 2 x 2 digital inputs, Sockets M12 x 1, 2 pneumatic outputs

AS-i AirBox, AS-i interface to FC lower parts, 2 inputs / 1 output NO/NC selectable (monostable), Connection to the pneumatic system by tube fittings, 1 x 2 or 2 x 1 digital inputs, Sockets M12 x 1, 1 pneumatic output (NO/NC selectable)

AS-i AirBox, 2 inputs / 1 output, AirBox supply via AS-i, 5/2-way slide valve free from overlapping, monostable, Three orientations of the flat cable are possible, Digital inputs, Addressing socket, AS-i profile S-3.F.F, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection

AS-i AirBox, 2 inputs / 2 outputs, AirBox supply via AS-i, 2 x 3/2-way slide valves free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, Addressing socket, AS-i profile S-3.F.F

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via AS-i, 2 x 3/2-way slide valves free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via external 24 V DC, 2 x 3/2-way slide valves free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket

AS-i AirBox, 4 inputs / 1 output , AirBox supply via AS-i, 5/2-way slide valve free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket

AS-i AirBox, 4 inputs / 1 output, AirBox supply via external voltage 24 V DC, 5/2-way slide valve free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket

AS-i AirBox, 2 inputs / 2 outputs, AirBox supply via AS-i, 5/2-way bistable slide valve free from overlapping, Three orientations of the flat cable are possible, AS-i flat cable connection, Addressing socket, AS-i profile S-3.F.F

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via AS-i, 5/2-way bistable slide valve free from overlapping, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via external 24 V DC, 5/2-way bistable slide valve free from overlapping, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via AS-i, 5/3-way slide valve free from overlapping, closed, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via external 24 V DC, 5/3-way slide valve free from overlapping, closed, Three orientations of the flat cable are possible, AS-i flat cable connection, Addressing socket, Version 2.11 and 3.0 with extended addressing mode

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via AS-i, 2 x 3/2-way slide valves free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, Addressing socket, AS-i profile S-7.F.F

AS-i AirBox, 2 inputs / 1 output, AirBox supply via AS-i, 5/2-way slide valve free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, Addressing socket, AS-i profile S-3.F.F

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via AS-i, 2 x 3/2-way slide valves free from overlapping, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via AS-i, 2 x 3/2-way slide valves free from overlapping, monostable, Three orientations of the flat cable are possible, Digital inputs, Addressing socket, AS-i profile S-7.F.F, Versions 2.11 and 3.0, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection

AS-i AirBox, 4 inputs / 1 output , AirBox supply via AS-i, 5/2-way slide valve free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via AS-i, 5/2-way bistable slide valve free from overlapping, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection