Baumer Capacitive Sensors

art. 11045948

special typeliquid level sensor for wastewater
nominal sensing distance Sn0,1 mm
mounting typenon-flush
output circuitNPN break function (NC)
operating temperature0 ... +50 °C

art. 10119679

nominal sensing distance Sn4 mm
nominal sensing distance Sn adjustable0,5 ... 4 mm
mounting typeflush
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 10119694

nominal sensing distance Sn8 mm
nominal sensing distance Sn adjustable2 ... 8 mm
mounting typeflush
output circuitPNP break function (NC)
operating temperature-25 ... +75 °C

art. 10119711

nominal sensing distance Sn15 mm
nominal sensing distance Sn adjustable4 ... 15 mm
mounting typeflush
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 11076813

nominal sensing distance Sn8 mm
mounting typeflush
GND electrodeno
operating temperature-25 ... +75 °C

art. 11050685

nominal sensing distance Sn12 mm
mounting typeflush
GND electrodeno
operating temperature-25 ... +75 °C

art. 10119714

nominal sensing distance Sn15 mm
nominal sensing distance Sn adjustable4 ... 15 mm
mounting typeflush
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 10119712

nominal sensing distance Sn15 mm
nominal sensing distance Sn adjustable4 ... 15 mm
mounting typeflush
output circuitPNP break function (NC)
operating temperature-25 ... +75 °C

art. 10112672

nominal sensing distance Sn5 mm
mounting typeflush
GND electrodeyes
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 10119700

nominal sensing distance Sn5 mm
mounting typeflush
GND electrodeyes
output circuitPNP break function (NC)
operating temperature-25 ... +75 °C

art. 11004520

special typesensor for high temperatures
nominal sensing distance Sn15 mm
nominal sensing distance Sn adjustable4 ... 15 mm
output circuitPNP break function (NC)
operating temperature-40 ... +200 °C

art. 10119685

nominal sensing distance Sn8 mm
nominal sensing distance Sn adjustable2 ... 8 mm
mounting typeflush
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C
Ripple immunity3 Vms
Power-up time≤ 10 s
Power supply8 … 35 V DC

art. 10127191

special typesensor for high temperatures
nominal sensing distance Sn15 mm
nominal sensing distance Sn adjustable4 ... 15 mm
output circuitPNP make function (NO)
operating temperature-40 ... +200 °C

art. 10164642

nominal sensing distance Sn0,5 mm
mounting typenon-flush
GND electrodeno
output circuitNPN make function (NO)
operating temperature0 ... +70 °C

art. 11039126

special typeliquid level sensor for wastewater
nominal sensing distance Sn0,1 mm
mounting typenon-flush
output circuitNPN make function (NO)
operating temperature0 ... +50 °C

art. 10129050

nominal sensing distance Sn0,5 mm
mounting typenon-flush
GND electrodeno
output circuitPNP make function (NO)
operating temperature0 ... +70 °C

art. 11017111

special typeliquid level sensor for wastewater
nominal sensing distance Sn0,1 mm
mounting typenon-flush
output circuitPNP make function (NO)
operating temperature0 ... +50 °C

art. 10164795

nominal sensing distance Sn0,5 mm
mounting typenon-flush
GND electrodeno
output circuitPNP break function (NC)
operating temperature0 ... +70 °C
nominal sensing distance Sn5 mm
mounting typenon-flush
GND electrodeno
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 11001668

nominal sensing distance Sn15 mm
nominal sensing distance Sn adjustable2 ... 15 mm
mounting typenon-flush
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 11001669

nominal sensing distance Sn15 mm
nominal sensing distance Sn adjustable2 ... 15 mm
mounting typenon-flush
output circuitNPN break function (NC)
operating temperature-25 ... +75 °C

art. 11001670

nominal sensing distance Sn15 mm
nominal sensing distance Sn adjustable2 ... 15 mm
mounting typenon-flush
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C
nominal sensing distance Sn5 mm
mounting typenon-flush
GND electrodeno
output circuitPNP break function (NC)
operating temperature-25 ... +75 °C

art. 11001671

nominal sensing distance Sn15 mm
nominal sensing distance Sn adjustable2 ... 15 mm
mounting typenon-flush
output circuitPNP break function (NC)
operating temperature-25 ... +75 °C

art. 11149600

special typeliquid level sensor for oil
mounting typenon-flush
versionadhesion resistant
output circuitvoltage output
operating temperature-40 ... +85 °C

art. 11001683

nominal sensing distance Sn8 mm
mounting typenon-flush
GND electrodeno
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 11001676

nominal sensing distance Sn30 mm
nominal sensing distance Sn adjustable5 ... 30 mm
mounting typenon-flush
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 10119682

nominal sensing distance Sn4 mm
nominal sensing distance Sn adjustable0,5 ... 4 mm
mounting typeflush
output circuitNPN break function (NC)
operating temperature-25 ... +75 °C

art. 10236345

nominal sensing distance Sn4 mm
nominal sensing distance Sn adjustable0,5 ... 4 mm
mounting typeflush
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

Baumer capacitive sensor photoBaumer capacitive sensors are transducers that convert non-electrical quantities to electrical capacitance values.

They are used to measure fluid, pressure, humidity, mechanical stress, etc. Their operation principle is similar to open electric capacitor.

The main advantages of capacitive sensors:

  • Contactless
  • They are available to work with any materials
  • High durability level

The sensors work at distance up to 30 mm. Its operating range is determined by EN 60947-5-2. Such equipment works optimally with aggressive environments due to non-contact technology. The quality of work does not depend on the color, material and other physical characteristics of an object.

Devices work with both conductive (electrical conductivity> 20 μS / cm.) and non-conductive (<20 μS / cm) medias. They also normally operate with optically reflecting surfaces.

The company produces capacitive sensors of the following main types:

  • With metal housing
  • With plastic housing
  • With flat design

In addition to various materials, the products are available in cylindrical, rectangular and proximity designs. Models of this series have the following protection class variants: IP65, IP67, IP 68, and IP69K.

Capacitive sensors by Baumer are universal units that work with any kind of environment. They are very robust, long-life and don`t exposed to significant damage from aggressive environments, due to the non-contact principle of action.

More detailed information you can see here: