PEPPERL+FUCHS AS-Interface


Pepperl+Fuchs VBA-4E4E-G12-ZAJ
Price on Request
One click request

AS-Interface sensor module

  • A/B slave with extended addressing possibility for up to 62 slaves
  • One-piece housing with stainless steel base
  • Installation without tools
  • Metal threaded inserts with SPEEDCON technology
  • Flat cable connection with cable piercing technique, variable flat cable guide
  • Communication monitoring, configurable
  • Inputs for 2-, 3-, and 4-wire sensors
  • DIN rail mounting
  • AS-Interface certificate
  • Automatic addressing with latest masters in the event of replacement

Pepperl+Fuchs VBA-8E8A8A-KE4-ZEL/E2L/SEL
Price on Request
One click request

AS-Interface safety module

  • Compact solution providing a large number of safe outputs
  • Functional switching of the safe outputs possible with standard outputs
  • 1 A/B diagnostic slave possible per safe output
  • 8 standard inputs for EDM
  • Up to SIL3 (EN 62061) and PLe (EN13849-1)

Pepperl+Fuchs VBA-BUZZER/LT-RD
Price on Request
One click request

Acknowledgment button


Pepperl+Fuchs VBA-LT2-G1
Price on Request
One click request

AS-Interface luminous push-button module

  • AS-Interface certificate
  • Degree of protection IP67
  • Flat or round cable connection (via standardized EMS base, not included with delivery)
  • Cable piercing method for flat cable
  • 2 integrated illuminated pushbuttons green red
  • Fault signal via LED

Pepperl+Fuchs VBA-LT2-G1-2YE
Price on Request
One click request

AS-Interface luminous push-button module

  • AS-Interface certificate
  • Degree of protection IP67
  • Flat or round cable connection (via standardized EMS base, not included with delivery)
  • Cable piercing method for flat cable
  • 2 integrated yellow illuminated pushbuttons
  • Fault signal via LED

Pepperl+Fuchs VBA-LT2-G1-Y
Price on Request
One click request

AS-Interface luminous push-button module

  • AS-Interface certificate
  • Degree of protection IP67
  • Flat or round cable connection (via standardized EMS base, not included with delivery)
  • Cable piercing method for flat cable
  • 2 integrated illuminated pushbuttons
  • Fault signal via LED
  • Variable colors

Pepperl+Fuchs VBG-CCL-G4F
Price on Request
One click request

AS-Interface gateway

  • Gateway according to AS-Interface specification 2.1 for up to 62 units
  • AS-Interface connection via flat cable and EMS standard bottom section (included delivery)
  • Degree of protection IP65
  • Voltage supply from AS-Interface
  • PLC functionality
  • Error diagnostics via LEDs and LC display

Pepperl+Fuchs VBG-CCL-K20-D-BV
Price on Request
One click request

AS-Interface gateway

  • Gateway compliant with AS-Interface specification 3.0
  • Fault diagnosis via LEDs and grafic display
  • Easy commissioning by graphic display
  • AS-Interface monitor read via display
  • Earth fault detection
  • AS-Interface noise detection

Pepperl+Fuchs VBG-CCL-K30-D-S32-EV
Price on Request
One click request

AS-Interface Gateway/Safety Monitor

  • Gateway and safety monitor in one housing
  • SafeLink
  • Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
  • Six safe electronic outputs
  • Integrated data decoupling
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection
  • Ethernet diagnostic interface
  • Connection to CC-Link

Pepperl+Fuchs VBG-DN-K20-D
Price on Request
One click request

AS-Interface gateway

  • Gateway compliant with AS-Interface specification 3.0
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection
  • Easy commissioning by graphic display
  • Commissioning, locally on the gateway or via AS-i Control Tools software
  • Fault diagnosis via LEDs and grafic display
  • AS-Interface monitor or extended AS-Interface diagnostic read via display
  • Ethernet diagnostic interface

Pepperl+Fuchs VBG-DN-K20-DMD
Price on Request
One click request

AS-Interface gateway

  • Gateway compliant with AS-Interface specification 3.0
  • 2 AS-Interface networks
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection
  • Easy commissioning by graphic display
  • Commissioning, locally on the gateway or via AS-i Control Tools software
  • Fault diagnosis via LEDs and grafic display
  • AS-Interface monitor or extended AS-Interface diagnostic read via display
  • Ethernet diagnostic interface

Pepperl+Fuchs VBG-DN-K20-DMD-BV
Price on Request
One click request

AS-Interface gateway

  • Gateway compliant with AS-Interface specification 3.0
  • 2 AS-Interface networks
  • Earth fault detection
  • AS-Interface noise detection
  • Easy commissioning by graphic display
  • Commissioning, locally on the gateway or via AS-i Control Tools software
  • Fault diagnosis via LEDs and grafic display
  • AS-Interface monitor or extended AS-Interface diagnostic read via display

Pepperl+Fuchs VBG-EC-K30-DMD-S32-EV
Price on Request
One click request

AS-Interface Gateway/Safety Monitor

  • Gateway and safety monitor in one housing
  • Connection to EtherCAT
  • SafeLink
  • Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
  • 2 AS-Interface networks
  • Six safe electronic outputs
  • Integrated data decoupling
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection
  • Ethernet diagnostic interface

Pepperl+Fuchs VBG-ENX-K20-D
Price on Request
One click request

AS-Interface gateway

  • Gateway compliant with AS-Interface specification 3.0
  • Connection to Ethernet Modbus TCP/IP
  • Dublicate addressing detection
  • Integrated webserver
  • Earth fault detection
  • AS-Interface noise detection
  • Ethernet diagnostic interface
  • Integrated switch allows line topology
  • DLR technology supports ring topology

Pepperl+Fuchs VBG-ENX-K20-D-EV24
Price on Request
One click request

AS-Interface gateway

  • Connection to Ethernet Modbus TCP/IP
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection
  • Ethernet diagnostic interface
  • Integrated switch allows line topology
  • DLR technology supports ring topology
  • AS-Interface POWER24

Pepperl+Fuchs VBG-ENX-K20-DMD
Price on Request
One click request

AS-Interface gateway

  • Gateway compliant with AS-Interface specification 3.0
  • Connection to Ethernet Modbus TCP/IP
  • 2 AS-Interface networks
  • Dublicate addressing detection
  • Integrated webserver
  • Earth fault detection
  • AS-Interface noise detection
  • Ethernet diagnostic interface
  • Integrated switch allows line topology
  • DLR technology supports ring topology

Pepperl+Fuchs VBG-ENX-K20-DMD-EV
Price on Request
One click request

AS-Interface gateway

  • Connection to Ethernet Modbus TCP/IP
  • 2 AS-Interface networks
  • Easy commissioning and fault diagnosis via LEDs and graphic display
  • Dublicate addressing detection
  • Integrated data decoupling
  • Integrated switch allows line topology
  • Integrated webserver
  • Earth fault detection
  • AS-Interface noise detection
  • Ethernet diagnostic interface
  • DLR technology supports ring topology

Pepperl+Fuchs VBG-ENX-K30-DMD-S16
Price on Request
One click request

AS-Interface Gateway/Safety Monitor

  • Gateway and safety monitor in one housing
  • Gateway compliant with AS-Interface specification 3.0
  • Connection to Ethernet Modbus TCP/IP
  • AS-Interface safety monitor with extended range of functions
  • Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
  • Memory card for configuration data
  • 2 AS-Interface networks
  • 2 safe output relays and 2 safe electronic outputs
  • Integrated switch allows line topology
  • DLR technology supports ring topology

Pepperl+Fuchs VBG-ENX-K30-DMD-S16-EV
Price on Request
One click request

AS-Interface Gateway/Safety Monitor

  • Gateway and safety monitor in one housing
  • Connection to Ethernet Modbus TCP/IP
  • SafeLink
  • Integrated data decoupling
  • Integrated webserver
  • Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
  • Memory card for configuration data
  • 2 AS-Interface networks
  • 2 safe output relays and 2 safe electronic outputs
  • Integrated switch allows line topology
  • DLR technology supports ring topology
  • Max. 32 independent safety loops

Pepperl+Fuchs VBG-MOD-K20-D
Price on Request
One click request

AS-Interface gateway

  • Connection to MODBUS RTU
  • Easy commissioning and fault diagnosis via LEDs and graphic display
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection
  • RS 232 diagnosis interface

Pepperl+Fuchs VBG-PB-K20-D
Price on Request
One click request

AS-Interface gateway

  • Connection to PROFIBUS DP
  • Easy commissioning and fault diagnosis via LEDs and graphic display
  • PROFIBUS DP V1 support
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection
  • RS 232 diagnosis interface

Pepperl+Fuchs VBG-PB-K20-D-BV
Price on Request
One click request

AS-Interface gateway

  • Connection to PROFIBUS DP
  • PROFIBUS DP V1 support
  • Easy commissioning and fault diagnosis via LEDs and graphic display
  • Earth fault detection
  • AS-Interface noise detection

Pepperl+Fuchs VBG-PB-K20-D-EV1
Price on Request
One click request

AS-Interface gateway

  • Connection to PROFIBUS DP
  • PROFIBUS DP V1 support
  • Easy commissioning and fault diagnosis via LEDs and graphic display
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection
  • Ethernet diagnostic interface

Pepperl+Fuchs VBG-PB-K20-D-EV24
Price on Request
One click request

AS-Interface gateway

  • Connection to PROFIBUS DP
  • Easy commissioning and fault diagnosis via LEDs and graphic display
  • PROFIBUS DP V1 support
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection
  • AS-Interface POWER24

Pepperl+Fuchs VBG-PB-K20-DMD
Price on Request
One click request

AS-Interface gateway

  • Connection to PROFIBUS DP
  • 2 AS-Interface networks
  • PROFIBUS DP V1 support
  • Easy commissioning and fault diagnosis via LEDs and graphic display
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection
  • RS 232 diagnosis interface

in international format without spaces