Baumer GXN1H
Absolute encoders
Voltage supply | 10...30 VDC |
Reverse polarity protection | Yes |
Consumption w/o load | ≤50 mA (24 VDC) |
Operating temperature | -25...+70 °C |
Inputs | TxD, RxD (RS232) Control signals UP/DOWN and zero ENABLE |
- Overview
- Comments
Code sequence | CW/CCW coded by connection |
Size (flange) | ø75 mm |
Initializing time typ. | 50 ms after power on |
Operating speed | ≤6000 rpm (mechanical) ≤6000 rpm (electric) |
manufacter SKU | GXN1H |
Number of cams | 250 |
Voltage supply | 10...30 VDC |
Protection DIN EN 60529 | IP 54 |
Reverse polarity protection | Yes |
Diagnostic functions | Code continuity check Signal frequency exceeded |
Materials | Housing: steel Flange: aluminium |
Connection | Cable 1 m, connector DSUB, 37pin |
Relative humidity | 95 % non-condensing |
Programming interface | RS232 |
Emitted interference | DIN EN 61000-6-4 |
Code | Binary |
Resistance | DIN EN 60068-2-6 Vibration 10 g, 16-2000 Hz DIN EN 60068-2-27 Shock 200 g, 6 ms |
Rotor moment of inertia | 20 gcm² |
Sensing method | Optical |
Inputs | TxD, RxD (RS232) Control signals UP/DOWN and zero ENABLE |
Weight approx. | 700 g |
Consumption w/o load | ≤50 mA (24 VDC) |
Shaft type | ø14 mm (through hollow shaft) |
Approval | UL approval / E63076 |
Output stages | PNP or NPN open collector |
Starting torque | ≤0.05 Nm (IP 54) |
Function | Multiturn |
Interfaces | Parallel (cams) 5 special outputs programmable |
Programmable parameters | Steps per revolution Number of revolutions 2 presets (limits) Rotation speed monitoring |
Steps per turn | ≤4096 / 12 bit |
Absolute accuracy | ±0.03 ° |
Operating temperature | -25...+70 °C |
Number of turns | ≤4096 / 12 bit |
Interference immunity | DIN EN 61000-6-2 |