Baumer HOG 10 + FSL
Incremental encoders

Baumer HOG 10 + FSL
Shaft insulation2.8 kV
Transmission length≤350 m at 100 kHz (HTL-P)
≤550 m at 100 kHz (TTL)
Interference immunityEN 61000-6-2
Operating temperature-40...+100 °C
-25...+100 °C (>3072 pulses per revolution)
-50...+100 °C (optional)
Item Number: HOG 10 + FSL
2626.38
-
+
Total price: 2626.38
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Operating torque typ. 6 Ncm
Emitted interference EN 61000-6-3
Consumption w/o load ≤100 mA
Range of switching speed (ns) 850...4500 rpm
(Δn = 2 rpm/s)
Output stages HTL-P (power linedriver)
TTL/RS422
Phase shift 90° ±20°
Speed (n) ≤1.25 · ns
Switching accuracy ±4 % (Δn = 2 rpm/s);
= +20 % (Δn = 1500 rpm/s)
Approval CE
Shaft type ø16...20 mm (blind hollow shaft)
ø17 mm (cone shaft 1:10)
Switching hysteresis ~40 % of switching speed
Admitted shaft load ≤450 N axial
≤600 N radial
Size (flange) ø105 mm
manufacter SKUHOG 10 + FSL
Operating temperature -40...+100 °C
-25...+100 °C (>3072 pulses per revolution)
-50...+100 °C (optional)
Sensing method Optical
Voltage supply 9...30 VDC
5 VDC ±5 %
Resistance IEC 60068-2-6
Vibration 5 g, 10-2000 Hz
IEC 60068-2-27
Shock 50 g, 11 ms
Scan ratio 40...60 %
Switching deviation cw-ccw rotation ≤3 %
Protection DIN EN 60529 IP 66
Pulses per revolution 300...5000
Weight approx. 2.2 kg
2.4 kg (with option M)
Connection 2x terminal box
3x terminal box (with option M)
Shaft insulation 2.8 kV
Interference immunity EN 61000-6-2
Transmission length ≤350 m at 100 kHz (HTL-P)
≤550 m at 100 kHz (TTL)
Output frequency ≤120 kHz
≤300 kHz (on request)
Reference signal Zero pulse, width 90°
Output switching capacity ≤6 A / 230 VAC; ≤1 A / 125 VDC
Rotor moment of inertia 400 gcm²
Minimum switching current 50 mA
Materials Housing: aluminium die-cast
Shaft: stainless steel
Switching outputs 1 output, speed control
HOG 10 + FSL output signals K1, K2, K0 + inverted
Error output (only EMS)

Comments

No comments yet

Write a comment