Pepperl+Fuchs NJ5-18GM-N
Inductive sensor
- Comfort series
- 5 mm flush
- Usable up to SIL 2 acc. to IEC 61508
Item Number:
NJ5-18GM-N
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Switching frequency | 0 ... 500 Hz |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
Effective internal inductance | max. 50 µH ; a cable length of 10 m is considered. |
Hysteresis | 3 % |
CE marking | [*PD-Z02585A*] |
Reduction factor r304 | 0.63 |
EAC conformity | TR CU 012/2011 |
Mission Time (TM) | 20 a |
Ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
Core cross-section | 0.75 mm2 |
Housing material | Stainless steel 1.4305 / AISI 303 |
MTTFd | 14110 a |
Appropriate type | NJ 5-18GM-N... |
Effective internal inductance | max. 50 µH ; a cable length of 10 m is considered. |
Installation | flush |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
Output type | NAMUR |
ATEX marking | II 1D Ex ia IIIC T135В°C Da The Ex-related marking can also be printed on the enclosed label. |
ATEX marking | II 1G Ex ia IIC T6…T1 Ga The Ex-related marking can also be printed on the enclosed label. |
Effective internal capacitance | max. 70 nF ; a cable length of 10 m is considered. |
Effective internal capacitance | max. 70 nF ; a cable length of 10 m is considered. |
Nominal voltage | 8.2 V (Ri approx. 1 kΩ) |
Operating voltage | 5 ... 25 V |
Sensing face | PBT |
ATEX marking | II 1G Ex ia IIC T6…T1 Ga The Ex-related marking can also be printed on the enclosed label. |
Reduction factor rAl | 0.21 |
Appropriate type | NJ 5-18GM-N... |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Connection type | cable PVC , 2 m |
Output type | 2-wire |
Appropriate type | NJ 5-18GM-N... |
CSA approval | cCSAus Listed, General Purpose |
CE marking | [*PD-Z02585A*] |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. |
Rated operating distance | 5 mm |
CE marking | [*PD-Z02585A*] |
Ambient temperature | -25 ... 100 В°C (-13 ... 212 В°F) |
Diagnostic Coverage (DC) | 0 % |
Assured operating distance | 0 ... 4.05 mm |
Effective internal capacitance | max. 70 nF ; a cable length of 10 m is considered. |
Degree of protection | IP66 / IP67 |
Reduction factor rCu | 0.18 |
Effective internal inductance | max. 50 µH ; a cable length of 10 m is considered. |
Switching function | Normally closed (NC) |
Use in the hazardous area | see instruction manuals |
People also buy
Comments
No comments yet