Sick AFM60E-S1AL004096
AFM60 Absolute encoder

Sick AFM60E-S1AL004096
  • High-resolution absolute encoders with up to 30 bits (AFM60) or up to 18 bits (AFS60)
  • Face mount flange, servo flange, blind or through hollow shaft
  • SSI, SSI + Incremental or SSI + Sin/Cos interface
Item Number: AFM60E-S1AL004096
557.70
-
+
Total price: 557.70
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Sick AFM60E-S1AL004096 is outdated.

Specification:

Part Number1037651
EMC:(according to EN 61000-6-2 and EN 61000-6-3)
Mechanical interface:Solid shaft, Servo flange
SET (electronic adjustment):H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V)
Shaft diameter:6 mm
Resolution:12 bit x 12 bit
Interface signals:Clock +, Clock -, Data +, Data-
Resolution power:4,096 x 4,096
MTTFd: mean time to dangerous failure:250 a (EN ISO 13849-1)
Power consumption:0.5 W (without load)
Permissible relative humidity:90 % (condensation of the optical scanning not permitted)
Enclosure rating:IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side
Code type:Gray
Operating torque:0.3 Ncm (+20 °C)
Code sequence:CW/CCW, parameter adjustable
Max. number of revolutions:4,096
Max. number of steps per revolution:4,096
Maximum operating speed:9,000 /min
Initialization time:50 ms
Moment of inertia of the rotor:6.2 gcm?
Measuring step:0.09 ° 360 ° / number of steps
Max. angular acceleration:500,000 rad/s?
CW/CCW (counting sequence when turning):L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V)
Permissible Load capacity of shaft:40 N (axial), 80 N (radial)
Connection type:Cable, 8-wire, universal, 3 m
Repeat accuracy:0.002 °
Resistance to vibration:20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
Operating voltage range:4.5 V DC ... 32 V DC
Error limits:± 0.2 °
Start up torque:0.5 Ncm (+20 °C)
Working temperature range:0 °C ... +85 °C
Reverse polarity protection:1
Storage temperature range:-40 °C ... +100 °C, without package
Clock frequency:1 MHz
Electrical interface:SSI/Gray
Resistance to shocks:50 g, 6 ms (according to EN 60068-2-27)
Measuring step deviation:± 0.2 °
Bearing lifetime:3.0 x 10^9 revolutions

Comments

No comments yet

Write a comment