Specification:

Part Number1052380
Permissible relative humidity:90 % (condensation of the optical scanning not permitted)
Start up torque:0.8 Ncm (+20 °C)
Maximum operating speed:9,000 /min
Shaft diameter:15 mm
SET (electronic adjustment):H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V)
Max. number of steps per revolution:4,096
Operating voltage range:4.5 V DC ... 32 V DC
Interface signals:Clock +, Clock -, Data +, Data-
Error limits:± 0.3 °
Max. number of revolutions:4,096
Clock frequency:1 MHz
Reverse polarity protection:1
Storage temperature range:-40 °C ... +100 °C, without package
Moment of inertia of the rotor:40 gcm²
Initialization time:50 ms
Electrical interface:SSI/Gray
Permissible movement radial static/dynamic:± 0.3 mm, ± 0.1 mm
Resistance to shocks:50 g, 6 ms (according to EN 60068-2-27)
Repeat accuracy:0.002 °
Resolution:12 bit x 12 bit
Connection type:Cable, 8-wire, universal, 1.5 m
Bearing lifetime:3.0 x 10^9 revolutions
Mechanical interface:Through hollow shaft
Permissible movement axial static/dynamic:± 0.5 mm, ± 0.2 mm
Measuring step deviation:± 0.2 °
Resistance to vibration:20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
Enclosure rating:IP 65 (according to IEC 60529), housing side, IP 65 (according to IEC 60529), shaft side
Max. angular acceleration:500,000 rad/s²
Measuring step:0.09 ° 360 ° / number of steps
CW/CCW (counting sequence when turning):L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V)
Power consumption:0.5 W (without load)
Resolution power:4,096 x 4,096
Code type:Gray
Working temperature range:0 °C ... +85 °C
MTTFd: mean time to dangerous failure:250 a (EN ISO 13849-1)
EMC:(according to EN 61000-6-2 and EN 61000-6-3)
Code sequence:CW/CCW, parameter adjustable
Operating torque:0.6 Ncm (+20 °C)