Sick BCG19-A1CM1015
Wire Draw (Rope) Encoders

Sick BCG19-A1CM1015
  • Measuring lengths of 1.25 m, 3 m, 5 m, and 10 m.
  • Very small dimension (55 ... 190 mm)
  • Modular system: encoder type, measuring length, and interface can be selected
Item Number: BCG19-A1CM1015
1312.74
-
+
Total price: 1312.74
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1061040
Housing material, wire draw mechanism:Plastic, Noryl
Initialization time:Ca. 50 ms
SET (electronic adjustment):Via SET cable
Number of steps per revolution:8,192
Resolution (wire draw + encoder):0.07 mm
Mounted mechanic:MRA-G190-110D3
Part number mechanic:5326242
Linearity:≤ ± 2 mm
Enclosure rating mechanic:IP 50
Mass (including encoder):2.16 kg
Resistance to vibration:30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
Measuring wire material:Highly flexible stranded steel 1.4401 stainless steel V4A
Supply voltage:4.5 V ... 32 V
Part number encoder:1037863
MTTFd: mean time to dangerous failure:250 a
Wire acceleration:8 m/s?
Operating speed:4 m/s
Working temperature range (mechanics):-30 °C ... +70 °C
Measuring wire diameter:0.55 mm
Code type:Gray
Working temperature range (combination):Wird definiert durch den h?heren mininalen und niedrigeren maximalen Wert des Arbeitstemperaturbereichs von Encoder und Mechanik
Electrical interface:SSI
Actual length of cable extension:10.2 m
Clock frequency:1 MHz
2 MHz
Resistance to shocks:70 g, 6 ms (according to EN 60068-2-27)
Life of wire draw mechanism:1 million cycles
Relative humidity / Condensation:90 % (condensation of the optical scanning not permitted)
Mass (mechanics):1.9 kg
Hysteresis:≤ 0.4 mm
Length of wire pulled out per revolution:555 mm
Enclosure rating encoder:IP 67
Spring return force:Ca. 9 N ... ca. 12 N
EMC:(according to EN 61000-6-2 and EN 61000-6-3)
Power consumption:0.7 W
Mass (measuring wire):1.2 g/m
Encoder:Absolute encoders
Mounted encoder:AFM60 SSI
Repeatability:≤ 0.2 mm
Connection type:Male connector M12, 8-pin, radial
Working temperature range (encoder):-30 °C ... +70 °C, with AFM60B, 0 °C ... +70 °C, with AFM60E
Measuring range:0 m ... 10 m

Comments