Sick BTF08-N1BM0299
Wire Draw (Rope) Encoders

Sick BTF08-N1BM0299
  • Absolute wire draw encoders
  • Modular measuring system with a wide selection of interfaces/measuring lengths
  • Measuring lengths: 2 m ... 50 m
Item Number: BTF08-N1BM0299
1540.11
-
+
Total price: 1540.11
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1060967
Mounted mechanic:MRA-F080-102D2
Linearity:≤ ± 2 mm
Protocol:PROFINET IO/ RT Class B
Number of steps per revolution:262,144
Mass (measuring wire):7.1 g/m
Mass (including encoder):1.5 kg
Working temperature range (encoder):-30 °C ... +70 °C
SET (electronic adjustment):Via PRESET push button or protocol
Hysteresis:≤ 2 mm
Resistance to vibration:30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
Actual length of cable extension:2.2 m
Connection type:Connector 3 x M12, 4-pin, axial
Address setting:Via DCP
Measuring wire diameter:1.35 mm
Resolution (wire draw + encoder):0.001 mm
Enclosure rating encoder:IP 67
Working temperature range (combination):Wird definiert durch den h?heren mininalen und niedrigeren maximalen Wert des Arbeitstemperaturbereichs von Encoder und Mechanik
Measuring wire material:Highly flexible stranded steel 1.4401 stainless steel V4A
Part number encoder:1059040
Supply voltage:10 V ... 30 V
EMC:(according to EN 61000-6-2 and EN 61000-6-3)
Power consumption:3 W
Wire acceleration:40 m/s?
Spring return force:6 N ... 14 N
Life of wire draw mechanism:1 million cycles
Working temperature range (mechanics):-30 °C ... +70 °C
Enclosure rating mechanic:IP 64
Part number mechanic:6028625
MTTFd: mean time to dangerous failure:80 a
Operating speed:4 m/s
Encoder:Absolute encoders
Mass (mechanics):1.3 kg
Resistance to shocks:100 g, 6 ms (according to EN 60068-2-27)
Encoder profile:V4.1 class3
Housing material, wire draw mechanism:Aluminum (anodised), die-cast zinc
Measuring range:0 m ... 2 m
Length of wire pulled out per revolution:200 mm
Mounted encoder:AFM60 PROFINET
Repeatability:≤ 1 mm
Relative humidity / Condensation:90 % (condensation of the optical scanning not permitted)
Electrical interface:PROFINET
Initialization time:Ca. 12 s

Comments

No comments yet