Sick BTF13-I1BM1099
Wire Draw (Rope) Encoders

Sick BTF13-I1BM1099
  • Absolute wire draw encoders
  • Modular measuring system with a wide selection of interfaces/measuring lengths
  • Measuring lengths: 2 m ... 50 m
Item Number: BTF13-I1BM1099
2166.45
-
+
Total price: 2166.45
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1060993
Address setting:Via DHCP / DEC-switches
Resistance to vibration:30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
Actual length of cable extension:10.2 m
Linearity:≤ ± 2 mm
Mass (measuring wire):7.1 g/m
Measuring wire material:Highly flexible stranded steel 1.4401 stainless steel V4A
Electrical interface:EtherNet/IP
MTTFd: mean time to dangerous failure:80 a
Power consumption:3 W
Protocol:EtherNet/IP IEC 61784-1
Enclosure rating encoder:IP 67
Enclosure rating mechanic:IP 64
Housing material, wire draw mechanism:Aluminum (anodised), plastic
Encoder profile:0 x 22
Encoder:Absolute encoders
Supply voltage:10 V ... 30 V
Relative humidity / Condensation:90 % (condensation of the optical scanning not permitted)
Part number mechanic:6028627
Part number encoder:1055331
Working temperature range (mechanics):-30 °C ... +70 °C
Repeatability:≤ 1.5 mm
Spring return force:10 N ... 20 N
Operating speed:4 m/s
Connection type:Connector 3 x M12, 4-pin, axial
Measuring wire diameter:1.35 mm
Measuring range:0 m ... 10 m
Length of wire pulled out per revolution:334.1 mm
Wire acceleration:40 m/s²
Hysteresis:≤ 3 mm
Number of steps per revolution:262,144
Working temperature range (combination):Wird definiert durch den höheren mininalen und niedrigeren maximalen Wert des Arbeitstemperaturbereichs von Encoder und Mechanik
Resistance to shocks:100 g, 6 ms (according to EN 60068-2-27)
Mounted mechanic:MRA-F130-110D2
Initialization time:Ca. 12 s
Resolution (wire draw + encoder):0.001 mm
Mounted encoder:AFM60 EtherNet/IP
Life of wire draw mechanism:1 million cycles
SET (electronic adjustment):Via PRESET push button or protocol
Mass (including encoder):3.7 kg
EMC:(according to EN 61000-6-2 and EN 61000-6-3)
Mass (mechanics):3.5 kg
Working temperature range (encoder):-30 °C ... +70 °C