Sick C4MT-04214ABB04DE0
Light curtains
- Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
- Compact cross section (15 mm x 32 mm) with no dead zones
- Cascadable twin stick design - sender and receiver in a single housing
Item Number:
C4MT-04214ABB04DE0
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Specification:
Part Number | 1207120 |
Switching current: | 300 mA |
Connection type extension connection: | Female connector M12, 5-pin |
Supply voltage: | 24 V DC (19.2 V DC ... 28.8 V DC) |
TM (mission time): | 20 a (EN ISO 13849) |
Power consumption: | ≤ 3 A |
Scanning range: | 0 m ... 4 m |
Cascaded: | + |
Ambient operating temperature: | -20 °C ... +55 °C |
Safe state in the event of a fault: | At least one OSSD is in the OFF state. |
Type of output: | PNP semiconductors, short-circuit protected, cross-circuit monitored |
Automatic beam coding: | + |
Switching voltage HIGH: | 24 V DC (VS - 2.25 V DC ... VS) |
Response time: | ≤ 14 ms |
Resolution: | 14 mm |
Category: | Category 4 (EN ISO 13849) |
Switching voltage LOW: | 2 V DC |
Configuration method: | Hard wired |
Protection class: | III (EN 61140) |
Air humidity: | 15 % ... 95 %, non-condensing |
Typical range: | 0 m ... 5 m |
Display elements: | LEDs |
Connection type: | Male connector M12, 5-pin |
Restart interlock (delivery status): | Deactivated |
Storage temperature: | -25 °C ... +70 °C |
Cable length: | 350 mm |
Safe SICK device communication via EFI/SDL: | - |
PFHd: | Cascaded systems: 1.3 1E-08 (EN ISO 13849) |
Shock resistance: | 10 g, 16 ms (EN 60068-2-27) |
Safety integrity level: | SIL3 (IEC 61508) SILCL3 (EN 62061) |
External device monitoring (delivery status): | Deactivated |
Housing cross-section (incl. system connection): | 15 mm x 32 mm |
Ripple: | ≤ 10 % |
Enclosure rating: | IP 65 (EN 60529) |
Vibration resistance: | 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) |
Synchronization: | Optical, without separate synchronization |
Housing material: | Aluminum alloy ALMGSI 0.5 |
Weight: | 155 g |
Integration via Flexi Soft safety controller: | CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET |
Conductor cross-section: | 0.34 mm? |
Type: | Type 4 (IEC 61496) |
Performance level: | PL e (EN ISO 13849) |
Restart interlock: | + |
Protective field height: | 420 mm |
Beam coding: | + |
Permitted cable length: | ≤ 20 m |
External device monitoring (EDM): | + |
People also buy
Comments
No comments yet