DFS60B-BGEA01024
DFS60
Specification:
Part Number | 1066044 |
Error limits: | ± 0.05 ° |
Working temperature range: | -30 °C ... +100 °C |
Moment of inertia of the rotor: | 40 gcm² |
Power consumption: | 0.5 W (without load) |
Permissible relative humidity: | 90 % (condensation of the optical scanning not permitted) |
Shaft diameter: | 14 mm |
Operating voltage range: | 10 V ... 32 V |
Measuring step: | Electronically/number of lines |
Connection type: | Connector M23, 12-pin, radial |
Maximum operating speed: | 6,000 /min |
MTTFd: mean time to dangerous failure: | 300 a (EN ISO 13849-1) |
Resistance to shocks: | 70 g (according to EN 60068-2-27) |
Pulses per revolution: | 1,024 |
Operating torque: | 0.6 Ncm (+20 °C) |
Load current max.: | 30 mA |
Bearing lifetime: | 3.6 x 10^10 revolutions |
Shaft material: | Metal |
Mechanical interface: | Blind hollow shaft |
Start up torque: | 0.8 Ncm (+20 °C) |
Reference signal, position: | 90 °, electronically, gated with A and B |
Storage temperature range: | -40 °C ... +100 °C, without package |
Resistance to vibration: | 30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) |
EMC: | (according to EN 61000-6-2 and EN 61000-6-3) |
Enclosure rating: | IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side |
Initialization time: | 40 ms |
Max. angular acceleration: | 500,000 rad/s² |
Electrical interface: | 10 V ... 32 V, HTL/Push pull, Connector M23, 12-pin, radial |
Measuring step deviation: | ± 0.01 ° |
Maximum output frequency: | 600 kHz |
Reference signal, number: | 1 |
Mass: | 0.2 kg |
Permissible movement radial static/dynamic: | ± 0.3 mm, ± 0.1 mm |