Sick DKS40-R5J00360
DKS40 Incremental encoder

Sick DKS40-R5J00360
  • Compact housing
  • Durable, low-cost design
  • Interfaces: Open collector NPN, TTL/RS-422 or HTL/push pull.
Item Number: DKS40-R5J00360
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

The product has been Discontinued by the Manufacturer!

Contact sales manager for a replacement.

Specification:

Part Number1034628
Moment of inertia of the rotor:6 gcm?
Permissible shaft loading radial/axial:40 N, 20 N
Resistance to vibration:20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6)
Storage temperature range:-40 °C ... +70 °C, without package
Error limits binary number of lines:0.09 °
Maximum operating speed:6,000 U/min
Measuring step deviation at non binary number of lines:0.07 °
Operating torque:0.4 Ncm (+20 °C)
Initialization time:40 s
Start up torque:0.6 Ncm (+20 °C)
Protection class housing side with cable outlet:IP 64
Working temperature range:0 °C ... +60 °C
Bearing lifetime:2 x 10^9 revolutions
Shaft diameter:8 mm x 13 mm
Supply voltage:10 V ... 30 V
Reference signal, number:1
Electrical interface:10 V ... 30 V, Open Collector NPN, Cable, universal, 0.5 m
Max. angular acceleration:3,6 x 10^9 rad/s?
Measuring step deviation at binary number of lines:0.035 °
Mass:0.18 kg
Air humidity:90 %
Connection type:Cable, universal, 0.5 m
Pulses per revolution:360
Operating power consumption (no load):40 mA
MTTFd: mean time to dangerous failure:600 a (EN ISO 13849-1)
Protection class shaft side:IP 64
Resistance to shocks:50 g, 7 ms (EN 60068-2-27)
Error limits non-binary number of lines:0.13 °
Protection class standard:IEC 60529
Maximum output frequency:50 kHz
Measuring step:90 °, Number of lines
Mechanical interface:Solid shaft, Face mount flange
Reference signal, position:90 °, electronically, gated with A and B
Output current:30 mA
EMC:EN 61000-6-2, EN 61000-6-3

Comments

No comments yet