Sick LFP0500-G1NMB
Level sensors

Sick LFP0500-G1NMB
  • Level monitoring in hygienic applications
  • Manually cutable monoprobe up to 4,000 mm long with Ra lessthan 0.8 µm
  • Process temperature up to 180 °C, process pressure up to 16 bar
Item Number: LFP0500-G1NMB
1123.16
-
+
Total price: 1123.16
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1052070
Repeatability:≤ 2 mm
Protection class:III
Hysteresis:Min. 2 mm, free adjustable
Output load:0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V
Upper signal level:20 mA ... 20.5 mA
Measurement:Switch, Continuous
Inductive load:< 1 H
Conductivity:No limitation
Medium:Fluids
Accuracy of sensor element:± 5 mm
Resolution:< 2 mm
Output current:< 100 mA
GOST approval:+
Housing design:With PMMA viewing window
Process pressure:-1 bar ... 16 bar
Max.probe load:6 Nm
Temperature drift:< 0.1 mm/K
IO-Link:+
Lower signal level:3.8 mA ... 4 mA
Capacitive load:100 nF
Probe length:500 mm
UL approval:+
Inactive area at probe end:10 mm
Initialization time:≤ 2 s
Ambient storage temperature:-40 °C ... +80 °C
Process temperature:-20 °C ... +150 °C
RoHS certificate:+
Housing material:303
EMC:EN 61326-1:2006, 2004/108/EG
Process connection:G ¾ A
Signal voltage HIGH:Vs - 2 V
EHEDG approval:+
Signal voltage LOW:≤ 2 V
Power consumption:≤ 75 mA at 24 V DC without output load
Enclosure rating:IP 67: EN 60529, IP 69K: EN 40050
Supply voltage:12 V DC ... 30 V DC
Response time:< 400 ms
Wetted parts:316L (Ra ≤ 0,8 µm), PEEK
Interference emission:EN 61000-6-4:2007
MTTF:194.3 a (EN ISO 13849-1)
Inactive area at process connector:25 mm
Interference resistance:EN 61000-6-2:2005
Connection type:Round connector M12 x 1, 5-pin
Ambient temperature operation:-20 °C ... +60 °C
Dielectricity constant:≥ 1.8 with coaxial tube, ≥ 5 for mono probe
Single- and continuous shock:EN 60068-2-27