Sick MOC3ZA-KAZ33D3

Sick MOC3ZA-KAZ33D3
  • Standstill monitoring by means of residual voltage measurement
  • 3 normally open and 1 normally closed positively guided safety contacts
  • 2 application diagnostic outputs for semiconductors
Item Number: MOC3ZA-KAZ33D3
711.76
-
+
Total price: 711.76
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number6044981
Nominal switching voltage:250 V AC
For UL 508 applications only:600 V AC
Standstill time ts:0.2 s ... 6 s, adjustable
Climate conditions according to:25/060/04 (EN 60068-1)
Safety integrity level:SIL3 (IEC 61508)
SILCL3 (EN 62061)
Safety outputs:Normally open contact (13/14, 23/24, 33/34)
Mounting:35 mm mounting rail according to EN 60715
Contact service life at 230 V / 5 A (AC) cos φ = 0.5:≥ 2 1E 05 switching operations
Enclosure rating terminals:IP 20
Contact configuration (safety contacts):3 contacts NO, 1 contact NC
TM (mission time):20 a (EN ISO 13849)
Measured/motor voltage:690 V AC
Power consumption:4 W
Semiconductor application diagnostics outputs (ON, ERR):Electrically isolated supply via A3/A4, Imax = 100 mA (short-circuit protected), ON for Release, ERR for Error
Standstill:+
Contact type:Relay, positively guided
Measurement inputs:L1/L2/L3
Hysteresis (for detection of running motor):100 %
Signal contacts 53/54 (normally open contact):3 A/250 V AC G. P.
Voltage threshold Uan:20 mV ... 400 mV, adjustable
Switching capacity in accordance with DC 13:2 A/24 V DC (EN 60947-5-1)
Safe state in the event of a fault:The N/O is open; in other words, the safety-related enabling current paths are interrupted.
Stop category:1 (EN 60204-1)
Dimensions (W x H x D):45 mm x 112 mm x 121 mm
Mechanical life:≥ 50 1E 06 switching operations
PFHd:41 1E-09 (EN ISO 13849)
Maximum switching frequency:1,200 /h
Supply voltage semiconductor diagnostic outputs (A3/A4):24 V DC (11 V DC ... 30 V DC)
Category:Category 4 (EN ISO 13849-1)
Vibration resistance:(EN 60068-2-6)
Switching capacity in accordance with AC 15:N/C: 2 A/230 V AC (EN 60947-5-1), N/O: 3 A/230 V AC (EN 60947-5-1)
Performance level:PL e (EN ISO 13849-1)
Response time:100 ms
Protection class housing:IP 40
Weight:400 g
Positively guided N/C contacts:Normally closed contact (41/42)