Sick PBT-RB6X0SG1SENAMA0Z
Pressure sensors

Sick PBT-RB6X0SG1SENAMA0Z
  • Gauge pressure measurement ranges from 0 ... 1 bar up to 0 … 600 bar
  • A large variety of available process connections
  • No moving parts: No mechanical wear, fatigue-proof, maintenance-free
Item Number: PBT-RB6X0SG1SENAMA0Z
170.50
-
+
Total price: 170.50
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number6039105
Connection type:Round connector M12 x 1, 4-pin, IP 67
Seal:NBR
Protection class III:+
Reference conditions:Reference conditions: According to IEC 61298-1
Weight sensor:Ca. 80 g
Relative humidity:45 % ... 75 %
Medium:Liquid and gaseous media
Pressure port:Standard
Electrical safety:Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 32 V DC, 36 V DC with 4 mA ... 20 mA, Reverse polarity protection: L+ towards M
Accuracy:≤ ± 0,6 % of Span (with non-linearity 0.25 % and with signal output 0 ... 5 V), ≤ ± 1 % of span (with non-linearity 0.25 %), ≤ ± 1,0 % of Span (with non-linearity 0.5 %), (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2))
Shock load:500 g according to IEC 60068-2-27 (mechanical shock)
Storage temperature:-30 °C ... +100 °C
Wetted parts:Pressure connection: stainless steel 316L, Pressure sensor: stainless steel 316L (for measurement ranges from 0 bar ... 10 bar rel stainless steel 13-8 PH)
Process temperature:-30 °C ... +100 °C
Vibration load:10 g according to IEC 60068-2-6 (vibration under resonance), 20 g optional
Measuring range:0 bar ... 6 bar
Isolation voltage:500 V DC
Gauge pressure:0 bar ... 1 bar up to bar ... 600 bar
Adjustment accuracy of zero signal:≤ 0.5 % of span typ., ≤ 0.8 % of span max. (with non-linerarity 0.5 %)
Process connection:G ¼ A according to DIN 3852-E
Housing material:Stainless steel 316L
Signal noise:≤ 0.3 % of span
Non-repeatability:≤ 0.1 % of span
Service life:Minimum 100 Mio. life cycles
Long-term drift/one-year stability:≤ 0.1 % of span according to IEC 61298-2
Rated temperature range:0 °C ... +80 °C
Response time:< 4 ms
Non-linearity:≤ ± 0.5 % ((Best Fit Straight Line, BFSL) according to IEC 61298-2)
Ambient temperature:0 °C ... +80 °C
Compound pressure:-1 bar ... 0 bar up to -1 bar ... +24 bar
Output signal:4 mA ... 20 mA
Absolute pressure:0 bar ... 1 bar up to 0 bar ... 25 bar
Pressure type:Gauge pressure
Enclosure rating:IP 67
CE-conformity:Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EC, EN 61 326-2-3
Power consumption:Max. 8 mA for voltage output signal, Signal current (max. 25 mA) for current output
Internal transmission fluid:Silicone oil (only with pressure ranges < 0 bar ... 10 bar and ≤ 0 bar abs ... 25 bar abs)
Hysteresis:≤ 0.16 % of span

Comments

No comments yet

Write a comment