Sick S30A-6111CL
Safety laser scanner

Sick S30A-6111CL
  • Direct integration in PROFINET IO safe bus system
  • 5.5 m protective field range
  • 4 switchable field sets
Item Number: S30A-6111CL
6634.49
-
+
Total price: 6634.49
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Specification:

Part Number1052593
Measured data output:+
Type of field set:Dual field sets
Number of simultaneously monitored protective fields:2
Expanded measured data output (CMS):-
Topology support:SNMP, MIB-2, LLDP nach IEEE 802.1AB
MRP client support
Number of field sets:4
Safe SICK device communication via EFI/SDL:-
Electrical connection:Optical fiber conductor (2 female connectors for SCRJ push-pull plug), system plug with or without connecting cable
Safety integrity level:SIL2 (IEC 61508), SILCL2 (EN 62061)
Category:Category 3 (EN ISO 13849)
TM (mission time):20 a (EN ISO 13849)
Supply voltage:16.8 V DC, 24 V DC, 28.8 V DC
Hazardous area protection (horizontal):+
Number of multiple samplings:Configurable 2 ... 16
Device properties:GSDML according to GSDML specification V2.25, PROFINET IO device with 2-port real-time switch according to PROFINET specification V2.2, PROFIsafe profile with 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4, Cycle time 4, 8, 16, 32 ms, etc.
Weight:3.3 kg
Response time:60 ms
Diagnostics:Application-related manufacturer-specific channel diagnostics and channel diagnostics for the PROFIsafe profile, individually switchable
Report system errors
Maintenance alerts for POF interfaces for signal quality
Cable diagnostics
Neighborhood alerts
Support for port statistics
I&M support from I&M0 to I&M4
Port properties:Auto-negotiation
Auto-crossover (MDIX)
Auto-polarity
100Base-FX
PFHd:8.0 1E-08 (EN ISO 13849)
Incremental encoder inputs:-
Interfaces for configuration and diagnostics using CDS:TCP port 9000 and UDP port 30718
RS-232
Number of monitoring cases:4
Static protective field switching:+
Integrated configuration memory:+
Maximum warning field range:49 m
Switch properties:Filtering Data Base according to IEEE 802.1D
6 prioritization levels for IEEE 802.1Q - Network prioritization
64 KB SRAM memory for caching telegrams, managed in 768-byte segments
Resource prioritization for network control and RTC2/3 frames
Telegram extension based on "Cut-through"
Port status (Disabled, Blocking, Forwarding)
Support for non-real-time and real-time data transfer
Configuration and diagnostics interface:RS-232
Conformance:Conformance Class B
Access protection (vertical):+
Laser class:1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001)
Dimensions (W x H x D):155 mm x 185 mm x 160 mm
Functions that are not supported:Multicast communication
Supervisor AR
MAC-pause mechanism in full duplex
Back-pressure in half duplex
Static learning
Broadcast Storm Control
Ambient operating temperature:-10 °C ... +50 °C
Protective field range:5.5 m
Performance level:PL d (EN ISO 13849)
Resolution:30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable
External device monitoring (EDM):-
Enclosure rating:IP 65 (EN 60529)
Type:Type 3 (IEC 61496)
Distance measuring range:49 m
Scan angle:190 °
Protection class:III (VDE 0106, EN 60950)
Hazardous area protection (vertical):+

Comments

No comments yet

Write a comment