Specification:

Part Number1052595
Supply voltage:16.8 V DC, 24 V DC, 28.8 V DC
Hazardous area protection (vertical):+
Number of monitoring cases:4
Laser class:1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001)
Interfaces for configuration and diagnostics using CDS:TCP port 9000 and UDP port 30718
RS-232
Distance measuring range:49 m
Weight:3.3 kg
Type of field set:Dual field sets
PFHd:8.0 1E-08 (EN ISO 13849)
Safe SICK device communication via EFI/SDL:-
Functions that are not supported:Multicast communication
Supervisor AR
MAC-pause mechanism in full duplex
Back-pressure in half duplex
Static learning
Broadcast Storm Control
Topology support:SNMP, MIB-2, LLDP nach IEEE 802.1AB
MRP client support
Port properties:Auto-negotiation
Auto-crossover (MDIX)
Auto-polarity
100Base-FX
Integrated configuration memory:+
Type:Type 3 (IEC 61496)
Enclosure rating:IP 65 (EN 60529)
Electrical connection:Optical fiber conductor (2 female connectors for SCRJ push-pull plug), system plug with or without connecting cable
Number of multiple samplings:Configurable 2 ... 16
Configuration and diagnostics interface:RS-232
Static protective field switching:+
Performance level:PL d (EN ISO 13849)
Maximum warning field range:49 m
Diagnostics:Application-related manufacturer-specific channel diagnostics and channel diagnostics for the PROFIsafe profile, individually switchable
Report system errors
Maintenance alerts for POF interfaces for signal quality
Cable diagnostics
Neighborhood alerts
Support for port statistics
I&M support from I&M0 to I&M4
Safety integrity level:SIL2 (IEC 61508), SILCL2 (EN 62061)
Device properties:GSDML according to GSDML specification V2.25, PROFINET IO device with 2-port real-time switch according to PROFINET specification V2.2, PROFIsafe profile with 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4, Cycle time 4, 8, 16, 32 ms, etc.
Hazardous area protection (horizontal):+
Access protection (vertical):+
TM (mission time):20 a (EN ISO 13849)
Number of field sets:4
Response time:60 ms
Conformance:Conformance Class B
Dimensions (W x H x D):155 mm x 185 mm x 160 mm
Incremental encoder inputs:-
Category:Category 3 (EN ISO 13849)
Switch properties:Filtering Data Base according to IEEE 802.1D
6 prioritization levels for IEEE 802.1Q - Network prioritization
64 KB SRAM memory for caching telegrams, managed in 768-byte segments
Resource prioritization for network control and RTC2/3 frames
Telegram extension based on "Cut-through"
Port status (Disabled, Blocking, Forwarding)
Support for non-real-time and real-time data transfer
Number of simultaneously monitored protective fields:2
Protective field range:7 m
Measured data output:+
Expanded measured data output (CMS):-
Protection class:III (VDE 0106, EN 60950)
Scan angle:190 °
Ambient operating temperature:-10 °C ... +50 °C
External device monitoring (EDM):-
Resolution:30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable