Specification:
Part Number | 1056429 |
Number of dynamic control inputs: | 2 |
Distance measuring range: | 30 m |
Safe SICK device communication via EFI/SDL: | + |
Type of field set: | Triple field sets |
Number of universal I/Os: | 5 |
Incremental encoder inputs: | + |
Number of monitoring cases: | 32 |
Number of field sets: | 8 |
Electrical connection: | System plug with or without connecting cable |
Performance level: | PL d (EN ISO 13849) |
Response time: | 80 ms |
Category: | Category 3 (EN ISO 13849) |
Access protection (vertical): | + |
Expanded measured data output (CMS): | - |
Weight: | 1.2 kg |
Number of static control inputs with EFI: | 5 |
Maximum warning field range: | 8 m |
Number of EDM inputs: | 1 |
Scan angle: | 270 ° |
Maximum output current: | 250 mA |
Laser class: | 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) |
Protective field range: | 3 m |
Resolution: | 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable |
Enclosure rating: | IP 65 (EN 60529) |
Protection class: | III (EN 50178) |
Safety integrity level: | SIL2 (IEC 61508), SILCL2 (EN 62061) |
PFHd: | 8.0 1E-08 (EN ISO 13849) |
Number of reset-/restart inputs: | 1 |
TM (mission time): | 20 a (EN ISO 13849) |
Number of application diagnostic outputs: | 3 |
Dimensions (W x H x D): | 102 mm x 152 mm x 106 mm |
Configuration and diagnostics interface: | RS-232 |
Static protective field switching: | + |
Data interface: | RS-422 |
Number of stand-by inputs: | 1 |
Hazardous area protection (horizontal): | + |
Supply voltage: | 16.8 V DC, 24 V DC, 30 V DC |
Integrated configuration memory: | + |
Type: | Type 3 (IEC 61496) |
Hazardous area protection (vertical): | + |
Number of safe outputs: | 2, Safety outputs (OSSD) |
Ambient operating temperature: | -10 °C ... +50 °C |
Measured data output: | + |
Number of static control inputs: | 3 |
Number of multiple samplings: | Configurable 2 ... 16 |
External device monitoring (EDM): | + |