Pepperl+Fuchs FB2201ER

Digital Output with Shutdown Input
Pepperl+Fuchs FB2201ER
464.10
One click request
Current limit53 mA
Rated voltage12 V DC , only in connection with the power supplies FB92**
Connectionchannel I: 1+, 4-
Environmental testEN 60068-2-14
Internal resistor315 andOmega;
Connectionbackplane bus
Line fault detectioncan be switched on/off for each channel via configuration tool
Watchdogwithin 0.5 s the device goes in safe state, e.g. after loss of communication
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Minimum pulse duration1 ms
Codingoptional mechanical coding via front socket
LED indicationLED green: supply
LED red: output line fault
LED yellow: status output
Occupied slots1
Switching point/switching hysteresis1.2 ... 2.1 mA / В± 0.2 mA
Open loop voltage22 V
Response time20 ms (depending on bus cycle time)
Number of channels1
EAC approvalRussia: RU C-IT.MIII06.B.00129
Connectionchannel I: 2+, 5-; channel II: 3+, 6-
Degree of protectionIEC 60529
Vibration resistanceEN 60068-2-6
Number of channels2
Damaging gasEN 60068-2-42
Line fault detectioncan be switched on/off for each channel via configuration tool , also when turned off (every 2.5 s the valve is turned on for 2 ms)
Electromagnetic compatibilityNE 21
Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance
EU-Type Examination CertificatePTB 97 ATEX 1074 U
Shock resistanceEN 60068-2-27
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
System informationThe module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.
Relative humidityEN 60068-2-56
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Interfacemanufacturer-specific bus to standard com unit
Power dissipation1.3 W
Degree of protectionIP20 (module) , a separate housing is required acc. to the system description
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Dimensions28 x 107 x 132 mm (1.1 x 4.2 x 5.2 inch)
Relative humidity95 % non-condensing
Internal resistor1 kandOmega;
Massapprox. 350 g
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
ATEX approvalPTB 97 ATEX 1075 ; PTB 97 ATEX 1074 U
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Connectionbackplane bus
Power consumption1.6 W