Pepperl+Fuchs FB2212ER

Digital Output with Shutdown Input
Pepperl+Fuchs FB2212ER
464.10
One click request
Internal resistor329 andOmega;
Interfacemanufacturer-specific bus to standard com unit
Connectionchannel I: 1+, 4-
ATEX approvalPTB 97 ATEX 1075 ; PTB 97 ATEX 1074 U
Internal resistor1 kandOmega;
Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Damaging gasEN 60068-2-42
Electromagnetic compatibilityNE 21
Codingoptional mechanical coding via front socket
Occupied slots1
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Response time20 ms (depending on bus cycle time)
Switching point/switching hysteresis1.2 ... 2.1 mA / В± 0.2 mA
Power consumption1.8 W
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Massapprox. 350 g
Line fault detectioncan be switched on/off for each channel via configuration tool
LED indicationLED green: supply
LED red: output line fault
LED yellow: status output
Power dissipation1.3 W
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
EU-Type Examination CertificatePTB 97 ATEX 1074 U
Relative humidity95 % non-condensing
Number of channels1
Open loop voltage25.3 V
Vibration resistanceEN 60068-2-6
Relative humidityEN 60068-2-56
Rated voltage12 V DC , only in connection with the power supplies FB92**
Degree of protectionIP20 (module) , a separate housing is required acc. to the system description
Watchdogwithin 0.5 s the device goes in safe state, e.g. after loss of communication
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
System informationThe module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance
Environmental testEN 60068-2-14
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Current limit53 mA
Dimensions28 x 107 x 132 mm (1.1 x 4.2 x 5.2 inch)
Minimum pulse duration1 ms
Line fault detectioncan be switched on/off for each channel via configuration tool , also when turned off (every 2.5 s the valve is turned on for 2 ms)
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Connectionchannel I: 2+, 5-; channel II: 3+, 6-
Connectionbackplane bus
Shock resistanceEN 60068-2-27
Number of channels2
Connectionbackplane bus
Degree of protectionIEC 60529
EAC approvalRussia: RU C-IT.MIII06.B.00129
in international format without spaces
All fields are required