Pepperl+Fuchs FB6213BR Digital Output

Pepperl+Fuchs FB6213BR
Item Number: FB6213BR
  • 4-channel
  • Outputs Ex ia
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • Line fault detection (LFD)
  • Positive or negative logic selectable
  • Simulation mode for service operations (forcing)
  • Permanently self-monitoring
  • Output with watchdog
Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments
Current limit42 mA
Damaging gasEN 60068-2-42
Degree of protectionIP20 (module) , a separate housing is required acc. to the system description
Watchdogwithin 0.5 s the device goes in safe state, e.g. after loss of communication
Occupied slots2
Open loop voltage23 V
Connectionchannel I: 9+, 10-; channel II: 11+, 12-; channel III: 13+, 14-; channel IV: 15+, 16-
Codingoptional mechanical coding via front socket
Relative humidityEN 60068-2-56
Massapprox. 750 g
Connectionbackplane bus / 24 V booster via wire ends
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Reaction time10 s
Dimensions57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch)
Response time10 ms (depending on bus cycle time)
Number of channels4
Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
ATEX approvalPTB 97 ATEX 1075 ; PTB 97 ATEX 1074 U
LED indicationLED green: supply
LED red: line fault , red flashing: communication error
Internal resistormax. 290 Ω
Environmental testEN 60068-2-14
Connectionbackplane bus
Input voltage range18.5 ... 32 V DC (SELV/PELV) booster voltage
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance
Power consumption0.15 W
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Vibration resistanceEN 60068-2-6
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Line fault detectioncan be switched on/off for each channel via configuration tool also when turned off (every 2.5 s the valve is turned on for 2 ms)
Degree of protectionIEC 60529
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Rated voltage12 V DC , only in connection with the power supplies FB92**
EAC approvalRussia: RU C-IT.MIII06.B.00129
Electromagnetic compatibilityNE 21
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Interfacemanufacturer-specific bus to standard com unit
EU-Type Examination CertificatePTB 97 ATEX 1074 U
Power dissipation3 W
Relative humidity95 % non-condensing
Shock resistanceEN 60068-2-27
System informationThe module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.

Comments

No comments yet

Write a comment